Effect of a capsular tension ring on axial intraocular lens position. Issue 1 (January 2015)
- Record Type:
- Journal Article
- Title:
- Effect of a capsular tension ring on axial intraocular lens position. Issue 1 (January 2015)
- Main Title:
- Effect of a capsular tension ring on axial intraocular lens position
- Authors:
- Weber, Maria
Hirnschall, Nino
Rigal, Karl
Findl, Oliver - Abstract:
- Abstract : Purpose : To assess the effect of a capsular tension ring (CTR) on the postoperative anterior chamber depth (ACD). Setting : Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria. Design : Prospective observer‐ and patient‐masked randomized trial. Methods : Bilateral small‐incision cataract surgery with implantation of a hydrophobic acrylic single‐piece intraocular lens (IOL) (Tecnis ZCB00) was performed using a standard technique. Each patient received a CTR in 1 eye (CTR group) and no CTR in the fellow eye (control group). The ACD was measured preoperatively with biometry (IOLMaster 500) and at 1 hour and 12 weeks postoperatively using partial coherence interferometry (ACMaster). The subjective refraction was assessed at 12 weeks. Results : Sixty eyes (30 patients) were included. Preoperatively, the mean axial length was 23.36 mm ± 1.55 (SD) (range 21.01 to 29.46 mm) in the CTR group and 23.37 ± 1.70 mm (range 21.14 to 28.84 mm) in the control group and the mean ACD was 3.06 ± 0.45 mm (range 2.25 to 4.16 mm) and 3.03 ± 0.47 mm (range 2.18 to 4.10 mm), respectively. The differences were not statistically significant ( P =.148 and P =.074, respectively). The mean postoperative ACD was 4.83 ± 0.46 mm (range 3.84 to 5.76 mm) in the CTR group and 4.81 ± 0.43 mm (range 3.67 to 5.65 mm) in the control group. The difference between the groups was not statistically significant ( P =.329). Conclusion : ImplantationAbstract : Purpose : To assess the effect of a capsular tension ring (CTR) on the postoperative anterior chamber depth (ACD). Setting : Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria. Design : Prospective observer‐ and patient‐masked randomized trial. Methods : Bilateral small‐incision cataract surgery with implantation of a hydrophobic acrylic single‐piece intraocular lens (IOL) (Tecnis ZCB00) was performed using a standard technique. Each patient received a CTR in 1 eye (CTR group) and no CTR in the fellow eye (control group). The ACD was measured preoperatively with biometry (IOLMaster 500) and at 1 hour and 12 weeks postoperatively using partial coherence interferometry (ACMaster). The subjective refraction was assessed at 12 weeks. Results : Sixty eyes (30 patients) were included. Preoperatively, the mean axial length was 23.36 mm ± 1.55 (SD) (range 21.01 to 29.46 mm) in the CTR group and 23.37 ± 1.70 mm (range 21.14 to 28.84 mm) in the control group and the mean ACD was 3.06 ± 0.45 mm (range 2.25 to 4.16 mm) and 3.03 ± 0.47 mm (range 2.18 to 4.10 mm), respectively. The differences were not statistically significant ( P =.148 and P =.074, respectively). The mean postoperative ACD was 4.83 ± 0.46 mm (range 3.84 to 5.76 mm) in the CTR group and 4.81 ± 0.43 mm (range 3.67 to 5.65 mm) in the control group. The difference between the groups was not statistically significant ( P =.329). Conclusion : Implantation of a CTR had no significant influence on the postoperative axial IOL position. Financial Disclosure : No author has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 41:Issue 1(2015)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 41:Issue 1(2015)
- Issue Display:
- Volume 41, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2015-0041-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2014.04.035 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16643.xml