Effect of high‐vacuum setting on phacoemulsification efficiency. Issue 9 (September 2017)
- Record Type:
- Journal Article
- Title:
- Effect of high‐vacuum setting on phacoemulsification efficiency. Issue 9 (September 2017)
- Main Title:
- Effect of high‐vacuum setting on phacoemulsification efficiency
- Authors:
- Ting, Darren Shu Jeng
Rees, Jon
Ng, Jia Yu
Allen, David
Steel, David H.W. - Abstract:
- Abstract : Purpose : To evaluate the effect of a high‐vacuum setting versus a low‐vacuum setting on the efficiency of phacoemulsification. Setting : Sunderland Eye Infirmary, Sunderland, United Kingdom. Design : Prospective clinical trial. Methods : Consecutive patients having cataract surgery in 2014 were recruited. Cataract surgery was performed by 2 experienced surgeons using a phacoemulsification machine with monitored forced infusion. The cataractous lens was split into 2 heminuclei using the stop‐and‐chop technique; in 1 heminucleus, phacoemulsification and aspiration used a high‐vacuum setting (600 mm Hg; treatment group) and in the other heminucleus, a low‐vacuum setting (350 mm Hg; control group). The high and low settings were alternated by case per the operating list to reduce surgeon bias. The main outcome measures were cumulative dissipated energy (CDE) and active heminucleus removal time. Results : One hundred sixty patients (160 eyes) were enrolled in the study, and 158 were included in the analysis. The CDE per heminucleus was significantly lower with the high‐vacuum setting than with the low‐vacuum setting (mean 2.81 percent‐seconds; 95% confidence interval (CI), 2.44‐3.21 versus 3.81 percent‐seconds; 95% CI, 3.38‐4.20; P < .001). The active heminucleus removal time was significantly shorter in the high‐vacuum group than the low‐vacuum group (mean 27.77 seconds; 95% CI, 25.26‐30.19 versus 33.59 seconds; 95% CI, 31.07‐35.92; P < .001). The observedAbstract : Purpose : To evaluate the effect of a high‐vacuum setting versus a low‐vacuum setting on the efficiency of phacoemulsification. Setting : Sunderland Eye Infirmary, Sunderland, United Kingdom. Design : Prospective clinical trial. Methods : Consecutive patients having cataract surgery in 2014 were recruited. Cataract surgery was performed by 2 experienced surgeons using a phacoemulsification machine with monitored forced infusion. The cataractous lens was split into 2 heminuclei using the stop‐and‐chop technique; in 1 heminucleus, phacoemulsification and aspiration used a high‐vacuum setting (600 mm Hg; treatment group) and in the other heminucleus, a low‐vacuum setting (350 mm Hg; control group). The high and low settings were alternated by case per the operating list to reduce surgeon bias. The main outcome measures were cumulative dissipated energy (CDE) and active heminucleus removal time. Results : One hundred sixty patients (160 eyes) were enrolled in the study, and 158 were included in the analysis. The CDE per heminucleus was significantly lower with the high‐vacuum setting than with the low‐vacuum setting (mean 2.81 percent‐seconds; 95% confidence interval (CI), 2.44‐3.21 versus 3.81 percent‐seconds; 95% CI, 3.38‐4.20; P < .001). The active heminucleus removal time was significantly shorter in the high‐vacuum group than the low‐vacuum group (mean 27.77 seconds; 95% CI, 25.26‐30.19 versus 33.59 seconds; 95% CI, 31.07‐35.92; P < .001). The observed differences were independent of the surgeon, patient age and sex, incision size, and nucleus density. No intraoperative complications were observed in either group. Conclusion : A high‐vacuum setting improved phacoemulsification efficiency using an active fluidics system and torsional phacoemulsification. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 43:Issue 9(2017)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 43:Issue 9(2017)
- Issue Display:
- Volume 43, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 43
- Issue:
- 9
- Issue Sort Value:
- 2017-0043-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-09
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.09.001 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16663.xml