Intraocular lens power calculation for eyes with high and low average keratometry readings: Comparison between various formulas. Issue 9 (September 2017)
- Record Type:
- Journal Article
- Title:
- Intraocular lens power calculation for eyes with high and low average keratometry readings: Comparison between various formulas. Issue 9 (September 2017)
- Main Title:
- Intraocular lens power calculation for eyes with high and low average keratometry readings: Comparison between various formulas
- Authors:
- Reitblat, Olga
Levy, Adi
Kleinmann, Guy
Lerman, Tsahi T.
Assia, Ehud I. - Abstract:
- Abstract : Purpose : To compare the accuracy of intraocular lens power prediction for eyes with average keratometry (K) readings greater than 46.00 diopters (D) and lower than 42.00 D. Setting : Ein‐Tal Eye Center, Tel‐Aviv, Israel. Design : Retrospective case series. Methods : Eyes having cataract extraction surgery with steep and flat preoperative corneal curvatures determined with the Lenstar‐LS900 device were enrolled. Refractive prediction errors for the Barrett Universal II, Haigis, Hill‐RBF, Hoffer‐Q, Holladay 1, Holladay 2, Olsen, and SRK/T formulas were compared. Optimized K values for the SRK/T formula were back‐calculated for each group. Validation was performed using an additional dataset. Results : The study comprised 171 eyes (79, K reading >46.00 D; 92, K reading <42.00 D). For K readings greater than 46.00 D, myopic errors were noted using the SRK/T and Hill‐RBF formulas and hyperopic errors using the Olsen C‐constant and Haigis (−0.31 D, −0.17 D, 0.18 D, and 0.17 D, respectively). The percentage of eyes with an absolute error within ±0.50 D from target refraction ranged from 60.8% (SRK/T) to 83.0% (Hill‐RBF). For K readings lower than 42.00 D, myopic errors were seen using the Haigis, Hill‐RBF, Hoffer‐Q, and Olsen‐C formulas (−0.31 D, −0.14 D, −0.22 D, and −0.17 D, respectively) and a hyperopic error using the SRK/T formula (0.16 D). The refractive prediction within ±0.50 D ranged between 75.0% (Haigis) and 96.7% (Barrett Universal II). Conclusions : PowerAbstract : Purpose : To compare the accuracy of intraocular lens power prediction for eyes with average keratometry (K) readings greater than 46.00 diopters (D) and lower than 42.00 D. Setting : Ein‐Tal Eye Center, Tel‐Aviv, Israel. Design : Retrospective case series. Methods : Eyes having cataract extraction surgery with steep and flat preoperative corneal curvatures determined with the Lenstar‐LS900 device were enrolled. Refractive prediction errors for the Barrett Universal II, Haigis, Hill‐RBF, Hoffer‐Q, Holladay 1, Holladay 2, Olsen, and SRK/T formulas were compared. Optimized K values for the SRK/T formula were back‐calculated for each group. Validation was performed using an additional dataset. Results : The study comprised 171 eyes (79, K reading >46.00 D; 92, K reading <42.00 D). For K readings greater than 46.00 D, myopic errors were noted using the SRK/T and Hill‐RBF formulas and hyperopic errors using the Olsen C‐constant and Haigis (−0.31 D, −0.17 D, 0.18 D, and 0.17 D, respectively). The percentage of eyes with an absolute error within ±0.50 D from target refraction ranged from 60.8% (SRK/T) to 83.0% (Hill‐RBF). For K readings lower than 42.00 D, myopic errors were seen using the Haigis, Hill‐RBF, Hoffer‐Q, and Olsen‐C formulas (−0.31 D, −0.14 D, −0.22 D, and −0.17 D, respectively) and a hyperopic error using the SRK/T formula (0.16 D). The refractive prediction within ±0.50 D ranged between 75.0% (Haigis) and 96.7% (Barrett Universal II). Conclusions : Power calculation for eyes with flat corneas and steep corneas requires the use of specific formulas for accurate postoperative results. An adjustment method of the SRK/T formula is proposed. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 43:Issue 9(2017)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 43:Issue 9(2017)
- Issue Display:
- Volume 43, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 43
- Issue:
- 9
- Issue Sort Value:
- 2017-0043-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-09
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.06.036 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16662.xml