Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. Issue 8 (August 2019)
- Record Type:
- Journal Article
- Title:
- Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. Issue 8 (August 2019)
- Main Title:
- Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography
- Authors:
- Igarashi, Akihito
Shimizu, Kimiya
Kato, Sayaka
Kamiya, Kazutaka - Abstract:
- Abstract : Purpose : To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS‐AquaPORT) can be predicted by angle‐to‐angle (ATA) and white‐to‐white (WTW) measurements obtained with anterior segment optical coherence tomography (AS‐OCT). Setting : Sanno Hospital, Tokyo, Japan. Design : Retrospective case series. Methods : Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept‐source AS‐OCT CASIA2 system. Results : The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), −6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance ( r = 0.27, P = .08). Conclusion : The ATA measurements had higherAbstract : Purpose : To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS‐AquaPORT) can be predicted by angle‐to‐angle (ATA) and white‐to‐white (WTW) measurements obtained with anterior segment optical coherence tomography (AS‐OCT). Setting : Sanno Hospital, Tokyo, Japan. Design : Retrospective case series. Methods : Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept‐source AS‐OCT CASIA2 system. Results : The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), −6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance ( r = 0.27, P = .08). Conclusion : The ATA measurements had higher reproducibility than the WTW measurements on AS‐OCT, making it is a more important predictor of postoperative vault. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 45:Issue 8(2019)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 45:Issue 8(2019)
- Issue Display:
- Volume 45, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 8
- Issue Sort Value:
- 2019-0045-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2019.02.020 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16636.xml