Astigmatic correction by intrastromal astigmatic keratotomy during femtosecond laser–assisted cataract surgery: Factors in outcomes. Issue 2 (February 2018)
- Record Type:
- Journal Article
- Title:
- Astigmatic correction by intrastromal astigmatic keratotomy during femtosecond laser–assisted cataract surgery: Factors in outcomes. Issue 2 (February 2018)
- Main Title:
- Astigmatic correction by intrastromal astigmatic keratotomy during femtosecond laser–assisted cataract surgery: Factors in outcomes
- Authors:
- Byun, Yong‐Soo
Kim, Seonjoo
Lazo, Marjorie Z.
Choi, Mi‐Hyun
Kang, Min‐Ji
Lee, Jee‐Hye
Yoo, Young‐Sik
Whang, Woong‐Joo
Joo, Choun‐Ki - Abstract:
- Abstract : Purpose : To evaluate the 6‐month outcomes of femtosecond laser astigmatic keratotomy (AK) combined with femtosecond laser–assisted cataract surgery and identify factors affecting the efficacy of astigmatic correction. Setting : Seoul St. Mary's Hospital, Catholic University of Korea, Seoul, South Korea. Design : Retrospective case series. Methods : Femtosecond laser AK was performed during femtosecond laser–assisted cataract surgery. The keratometric astigmatism, refractive cylinder, corneal hysteresis (CH), and corneal resistance factor (CRF) were measured preoperatively and postoperatively at 1 week, 2 months, and 6 months. Vector analysis to evaluate the 6‐month outcomes of femtosecond laser AK and univariable regression analysis to determine the factors influencing the correction index were performed. Results : The study enrolled 89 eyes of 89 patients. The stigmatism type, CH, CRF, and absolute angle of error showed significant correlations with the correction index ( P = .041, P = .029, P = .044, and P < .001, respectively). There was a significant difference in the correction index and no difference in keratometric astigmatism between with‐the‐rule (WTR), against‐the‐rule (ATR), and oblique astigmatism ( P = .044). The keratometric astigmatism with ATR and oblique astigmatism (0.66 diopter [D] ± 0.42 [SD] and 0.46 ± 0.27 D, respectively) was significantly lower than the refractive cylinder (0.92 ± 0.56 D and 0.78 ± 0.43 D, respectively) ( P < .05); thisAbstract : Purpose : To evaluate the 6‐month outcomes of femtosecond laser astigmatic keratotomy (AK) combined with femtosecond laser–assisted cataract surgery and identify factors affecting the efficacy of astigmatic correction. Setting : Seoul St. Mary's Hospital, Catholic University of Korea, Seoul, South Korea. Design : Retrospective case series. Methods : Femtosecond laser AK was performed during femtosecond laser–assisted cataract surgery. The keratometric astigmatism, refractive cylinder, corneal hysteresis (CH), and corneal resistance factor (CRF) were measured preoperatively and postoperatively at 1 week, 2 months, and 6 months. Vector analysis to evaluate the 6‐month outcomes of femtosecond laser AK and univariable regression analysis to determine the factors influencing the correction index were performed. Results : The study enrolled 89 eyes of 89 patients. The stigmatism type, CH, CRF, and absolute angle of error showed significant correlations with the correction index ( P = .041, P = .029, P = .044, and P < .001, respectively). There was a significant difference in the correction index and no difference in keratometric astigmatism between with‐the‐rule (WTR), against‐the‐rule (ATR), and oblique astigmatism ( P = .044). The keratometric astigmatism with ATR and oblique astigmatism (0.66 diopter [D] ± 0.42 [SD] and 0.46 ± 0.27 D, respectively) was significantly lower than the refractive cylinder (0.92 ± 0.56 D and 0.78 ± 0.43 D, respectively) ( P < .05); this was not the case for WTR astigmatism. Conclusions : The efficacy of femtosecond laser AK was affected by the biomechanical properties of the cornea and astigmatism type. Further studies incorporating the individual biomechanical properties of the cornea and total corneal astigmatism in a nomogram are recommended. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 44:Issue 2(2018)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 44:Issue 2(2018)
- Issue Display:
- Volume 44, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2018-0044-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.11.018 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16664.xml