New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism. Issue 2 (February 2018)
- Record Type:
- Journal Article
- Title:
- New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism. Issue 2 (February 2018)
- Main Title:
- New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism
- Authors:
- Canovas, Carmen
Alarcon, Aixa
Rosén, Robert
Kasthurirangan, Sanjeev
Ma, Joseph J.K.
Koch, Douglas D.
Piers, Patricia - Abstract:
- Abstract : Purpose : To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Setting : Abbott Medical Optics, Inc., Groningen, the Netherlands. Design : Retrospective case report. Methods : In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon‐estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. Results : The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism ( P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against‐the‐rule, with‐the‐rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups ( P < .001). Conclusions : The use of the new PCA algorithm decreased theAbstract : Purpose : To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Setting : Abbott Medical Optics, Inc., Groningen, the Netherlands. Design : Retrospective case report. Methods : In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon‐estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. Results : The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism ( P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against‐the‐rule, with‐the‐rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups ( P < .001). Conclusions : The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 44:Issue 2(2018)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 44:Issue 2(2018)
- Issue Display:
- Volume 44, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2018-0044-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.11.008 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16664.xml