Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens. Issue 12 (December 2019)
- Record Type:
- Journal Article
- Title:
- Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens. Issue 12 (December 2019)
- Main Title:
- Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens
- Authors:
- Kato, Sayaka
Shimizu, Kimiya
Igarashi, Akihito
Kawamorita, Takushi - Abstract:
- Abstract : Purpose: : To compare kinetic visual acuity, stereopsis, ocular deviation, and fusion amplitude before and after implantable collamer lens (ICL) surgery. Setting: : Sanno Hospital. Design: : Retrospective analysis. Methods: : The charts of adult patients who underwent implantation of an ICL with a central aquaport (V4c) for emmetropia were reviewed. The mean preoperative spherical equivalent and subjective astigmatism were ‐7.87 diopters (D) ± 3.13 (SD) and ‐0.75 ± 0.78 D, respectively. All measurements were obtained with full refraction before surgery and without spectacle correction after surgery. The kinetic visual acuity was measured with the AS‐4D device. Stereopsis and ocular deviation were measured with the Titmus Stereotest and an alternate prism cover test, respectively. Fusion amplitude was determined from breakpoints measured using a prism. Results: : The study comprised 29 adult patients (58 eyes). One month postoperatively, the mean safety and efficacy indices were 1.13 ± 0.20 and 0.96 ± 0.25, respectively, and 57 eyes (98.7%) were within ± 0.5 D of the target correction. The mean kinetic visual acuity (logarithm of the minimum angle of resolution) was 0.30 ± 0.21 preoperatively and 0.20 ± 0.15 (Snellen 20/40 versus 20/32) postoperatively and the mean stereopsis (seconds of arc), 48.5 ± 1.6 versus 41.5 ± 1.1; both improved significantly ( P < .001 and P = .012, respectively). The mean distance ocular deviation (‐4.0 ± 3.8 prism diopters [Δ] versus 2.8Abstract : Purpose: : To compare kinetic visual acuity, stereopsis, ocular deviation, and fusion amplitude before and after implantable collamer lens (ICL) surgery. Setting: : Sanno Hospital. Design: : Retrospective analysis. Methods: : The charts of adult patients who underwent implantation of an ICL with a central aquaport (V4c) for emmetropia were reviewed. The mean preoperative spherical equivalent and subjective astigmatism were ‐7.87 diopters (D) ± 3.13 (SD) and ‐0.75 ± 0.78 D, respectively. All measurements were obtained with full refraction before surgery and without spectacle correction after surgery. The kinetic visual acuity was measured with the AS‐4D device. Stereopsis and ocular deviation were measured with the Titmus Stereotest and an alternate prism cover test, respectively. Fusion amplitude was determined from breakpoints measured using a prism. Results: : The study comprised 29 adult patients (58 eyes). One month postoperatively, the mean safety and efficacy indices were 1.13 ± 0.20 and 0.96 ± 0.25, respectively, and 57 eyes (98.7%) were within ± 0.5 D of the target correction. The mean kinetic visual acuity (logarithm of the minimum angle of resolution) was 0.30 ± 0.21 preoperatively and 0.20 ± 0.15 (Snellen 20/40 versus 20/32) postoperatively and the mean stereopsis (seconds of arc), 48.5 ± 1.6 versus 41.5 ± 1.1; both improved significantly ( P < .001 and P = .012, respectively). The mean distance ocular deviation (‐4.0 ± 3.8 prism diopters [Δ] versus 2.8 ± 3.6 Δ; P = .002) and near ocular deviation (‐6.5 ± 6.7 Δ versus 5.4 ± 6.9 Δ; P = .04) decreased significantly. The fusion amplitude increased for near vision only. Conclusions: : ICL implantation improved kinetic visual acuity and stereopsis, decreased ocular deviation, and increased near fusion amplitude. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 45:Issue 12(2019)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 45:Issue 12(2019)
- Issue Display:
- Volume 45, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 12
- Issue Sort Value:
- 2019-0045-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2019.08.009 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16622.xml