Changes in ocular biomechanics after femtosecond laser creation of a laser in situ keratomileusis flap. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Changes in ocular biomechanics after femtosecond laser creation of a laser in situ keratomileusis flap. Issue 1 (January 2016)
- Main Title:
- Changes in ocular biomechanics after femtosecond laser creation of a laser in situ keratomileusis flap
- Authors:
- Leccisotti, Antonio
Fields, Stefania V.
Moore, Johnny
Shah, Sunil
Moore, Tara C.B. - Abstract:
- Abstract : Purpose : To evaluate ocular biomechanical parameters with the Corvis ST, a noncontact tonometer combined with an ultra‐high‐speed Scheimpflug camera, before and after creation of a femtosecond laser–created laser in situ keratomileusis (LASIK) flap. Setting : Private practice, Siena, Italy. Design : Prospective consecutive study. Methods : Right eyes of patients having LASIK were assessed with the dynamic Scheimpflug camera before and after femtosecond laser (LDV Z4) flap creation but before mechanical flap lifting. Results : Twenty‐eight eyes of 28 patients were evaluated. Before flap creation, the mean values on the dynamic Scheimpflug camera were intraocular pressure (IOP), 15.04 mm Hg ± 3.99 (SD); central pachymetry, 550.8 ± 101.0 μm; applanation 1 length, 1.721 ± 0.134 mm; applanation 2 length, 1.674 ± 0.287 mm; applanation 1 velocity, 0.126 ± 0.031 m/s; and deflection amplitude, 1.039 ± 0.141 mm. After flap creation, the mean values were IOP, 16.10 ± 3.11 mm Hg (95% confidence interval [CI], 0.44‐1.78; P < .05); central pachymetry, 561.8 ± 35.9 μm (95% CI, −28.9 to 50.9; P = .21); applanation 1 length, 1.789 ± 0.1492 mm (95% CI, 0.003‐0.134; P < .05); applanation 2 length, 1.759 ± 0.259 mm (95% CI, −0.005 to 0.173; P = .08); applanation 1 velocity, 0.136 ± 0.022 m/s (95% CI, 0.001‐0.017; P < .05); and deflection amplitude, 1.029 ± 0.151 mm (95% CI: −0.043 to 0.025; P = .34). Conclusion : The dynamic Scheimpflug camera showed changes in biomechanicalAbstract : Purpose : To evaluate ocular biomechanical parameters with the Corvis ST, a noncontact tonometer combined with an ultra‐high‐speed Scheimpflug camera, before and after creation of a femtosecond laser–created laser in situ keratomileusis (LASIK) flap. Setting : Private practice, Siena, Italy. Design : Prospective consecutive study. Methods : Right eyes of patients having LASIK were assessed with the dynamic Scheimpflug camera before and after femtosecond laser (LDV Z4) flap creation but before mechanical flap lifting. Results : Twenty‐eight eyes of 28 patients were evaluated. Before flap creation, the mean values on the dynamic Scheimpflug camera were intraocular pressure (IOP), 15.04 mm Hg ± 3.99 (SD); central pachymetry, 550.8 ± 101.0 μm; applanation 1 length, 1.721 ± 0.134 mm; applanation 2 length, 1.674 ± 0.287 mm; applanation 1 velocity, 0.126 ± 0.031 m/s; and deflection amplitude, 1.039 ± 0.141 mm. After flap creation, the mean values were IOP, 16.10 ± 3.11 mm Hg (95% confidence interval [CI], 0.44‐1.78; P < .05); central pachymetry, 561.8 ± 35.9 μm (95% CI, −28.9 to 50.9; P = .21); applanation 1 length, 1.789 ± 0.1492 mm (95% CI, 0.003‐0.134; P < .05); applanation 2 length, 1.759 ± 0.259 mm (95% CI, −0.005 to 0.173; P = .08); applanation 1 velocity, 0.136 ± 0.022 m/s (95% CI, 0.001‐0.017; P < .05); and deflection amplitude, 1.029 ± 0.151 mm (95% CI: −0.043 to 0.025; P = .34). Conclusion : The dynamic Scheimpflug camera showed changes in biomechanical properties after femtosecond creation of a LASIK flap as indicated by an increased applanation 1 length and applanation 1 velocity. Financial Disclosure : No author has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 42:Issue 1(2016)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 42:Issue 1(2016)
- Issue Display:
- Volume 42, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2016-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2015.07.047 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16627.xml