Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: Comparison of methodologies. Issue 2 (February 2016)
- Record Type:
- Journal Article
- Title:
- Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: Comparison of methodologies. Issue 2 (February 2016)
- Main Title:
- Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: Comparison of methodologies
- Authors:
- Reitblat, Olga
Levy, Adi
Kleinmann, Guy
Abulafia, Adi
Assia, Ehud I. - Abstract:
- Abstract : Purpose : To compare the accuracy of different methods that consider posterior corneal curvature in toric intraocular lens (IOL) calculations. Setting : Ein‐Tal Eye Center, Tel‐Aviv, Israel. Design : Retrospective comparative case series. Methods : Consecutive cases of toric IOL implantation and preoperative measurements by optical biometry with optical low‐coherence reflectometry (OLCR) (Lenstar LS 900) and a Scheimpflug camera (Pentacam) were retrospectively reviewed. Five methods of toric IOL calculation were compared as follows: (1) anterior corneal astigmatism using OLCR, (2) application of the Baylor nomogram, (3) posterior tomography combined with anterior corneal measurements using vector summation, (4) the Scheimpflug camera's true net power, and (5) total corneal refractive power. Toric IOL astigmatic power and axis, aiming for the lowest residual astigmatism, were selected according to these methods. Simulated residual refraction was calculated for each method based on manifest refraction and measured IOL alignment more than 3 weeks after surgery. Results : The study included 115 eyes of 92 patients. The median simulated residual astigmatism was lower when based on vector summation of anterior and posterior astigmatisms than with calculations based on anterior corneal measurements only, application of the Baylor nomogram, true net power, and total corneal refractive power readings (0.49 diopters [D] versus 0.70 D, 0.60 D, 0.64 D, and 0.76 D,Abstract : Purpose : To compare the accuracy of different methods that consider posterior corneal curvature in toric intraocular lens (IOL) calculations. Setting : Ein‐Tal Eye Center, Tel‐Aviv, Israel. Design : Retrospective comparative case series. Methods : Consecutive cases of toric IOL implantation and preoperative measurements by optical biometry with optical low‐coherence reflectometry (OLCR) (Lenstar LS 900) and a Scheimpflug camera (Pentacam) were retrospectively reviewed. Five methods of toric IOL calculation were compared as follows: (1) anterior corneal astigmatism using OLCR, (2) application of the Baylor nomogram, (3) posterior tomography combined with anterior corneal measurements using vector summation, (4) the Scheimpflug camera's true net power, and (5) total corneal refractive power. Toric IOL astigmatic power and axis, aiming for the lowest residual astigmatism, were selected according to these methods. Simulated residual refraction was calculated for each method based on manifest refraction and measured IOL alignment more than 3 weeks after surgery. Results : The study included 115 eyes of 92 patients. The median simulated residual astigmatism was lower when based on vector summation of anterior and posterior astigmatisms than with calculations based on anterior corneal measurements only, application of the Baylor nomogram, true net power, and total corneal refractive power readings (0.49 diopters [D] versus 0.70 D, 0.60 D, 0.64 D, and 0.76 D, respectively) ( P < .001). Conclusions : Residual astigmatism after toric IOL implantation can be reduced by appropriate consideration of the posterior corneal astigmatism. Using methods that take into account the effect of the posterior cornea in toric IOL calculations is suggested. Financial Disclosures : Drs. Assia and Kleinmann are consultants to Hanita Lenses, Israel. Dr. Abulafia received a speaker's fee from Haag‐Streit AG. No other author has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 42:Issue 2(2016)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 42:Issue 2(2016)
- Issue Display:
- Volume 42, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue:
- 2
- Issue Sort Value:
- 2016-0042-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-02
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2015.11.036 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16643.xml