Adaptive localised region and edge‐based active contour model using shape constraint and sub‐global information for uterine fibroid segmentation in ultrasound‐guided HIFU therapy. Issue 12 (12th October 2017)
- Record Type:
- Journal Article
- Title:
- Adaptive localised region and edge‐based active contour model using shape constraint and sub‐global information for uterine fibroid segmentation in ultrasound‐guided HIFU therapy. Issue 12 (12th October 2017)
- Main Title:
- Adaptive localised region and edge‐based active contour model using shape constraint and sub‐global information for uterine fibroid segmentation in ultrasound‐guided HIFU therapy
- Authors:
- Liao, Xiangyun
Yuan, Zhiyong
Tong, Qianqian
Zhao, Jianhui
Wang, Qiong - Abstract:
- Abstract : Uterine fibroids segmentation in ultrasound images is of great importance in the definition of intra‐operative planning of ultrasound‐guided high‐intensity focused ultrasound (HIFU) therapy. However, it is challenging to obtain accurate, robust and efficient uterine fibroid segmentation due to low quality of ultrasound images. In this study, the authors propose a novel adaptive localised region and edge‐based active contour model using shape constraint and sub‐global information to accurately and efficiently segment the uterine fibroids in ultrasound images with robustness against initial contour. The authors first define adaptive local radius for the localised region‐based model and combine it with the edge‐based model to accurately and efficiently capture image's heterogeneous features and edge features. Then, they incorporate a shape constraint to reduce boundary leakage or excessive contraction to obtain more accurate segmentation. To overcome the initialisation sensitivity, they introduce the sub‐global information to prevent the curve from trapping into the local minima and obtain robust results. Furthermore, the authors optimise computation by adaptively sharing local region and employing the multi‐scale segmentation method to achieve efficient segmentation. The proposed method is validated by uterine fibroid ultrasound images in HIFU therapy and the results demonstrate that it can achieve accurate, robust and efficient segmentation.
- Is Part Of:
- IET image processing. Volume 11:Issue 12(2017)
- Journal:
- IET image processing
- Issue:
- Volume 11:Issue 12(2017)
- Issue Display:
- Volume 11, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 11
- Issue:
- 12
- Issue Sort Value:
- 2017-0011-0012-0000
- Page Start:
- 1142
- Page End:
- 1151
- Publication Date:
- 2017-10-12
- Subjects:
- ultrasonic imaging -- medical image processing -- image segmentation
adaptive localised region -- edge‐based active contour model -- shape constraint -- subglobal information -- uterine fibroid segmentation -- ultrasound‐guided HIFU therapy -- ultrasound images -- ultrasound‐guided high‐intensity focused ultrasound therapy -- intraoperative planning -- adaptive local radius -- localised region‐based model -- image heterogeneous features -- edge features -- boundary leakage -- initialisation sensitivity -- multiscale segmentation method
Image processing -- Periodicals
621.36705 - Journal URLs:
- http://digital-library.theiet.org/content/journals/iet-ipr ↗
http://ieeexplore.ieee.org/servlet/opac?punumber=4149689 ↗
http://www.ietdl.org/IET-IPR ↗
https://ietresearch.onlinelibrary.wiley.com/journal/17519667 ↗
http://www.theiet.org/ ↗ - DOI:
- 10.1049/iet-ipr.2016.0651 ↗
- Languages:
- English
- ISSNs:
- 1751-9659
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4363.252600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16614.xml