Comparison of the bone marrow trephine sample quality between OnControl drill system and the Jamshidi needle. (19th February 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of the bone marrow trephine sample quality between OnControl drill system and the Jamshidi needle. (19th February 2019)
- Main Title:
- Comparison of the bone marrow trephine sample quality between OnControl drill system and the Jamshidi needle
- Authors:
- Forwood, Kathryn M.
Lee, Edwin
Crispin, Philip J. - Abstract:
- Abstract: Introduction: Bone marrow biopsies are a key diagnostic and monitoring intervention in haematology with manual bone marrow techniques the established method of choice. Powered biopsy devices are now available, but are not widely used in haematology. This study compared the quality of bone marrow trephines obtained with the Jamshidi needle and OnControl powered drill system. Methods: Retrospective analysis was undertaken on trephine samples prior to and after implementation of the OnControl drill system. Trephine size and quality were assessed independently by three pathologists and compared between techniques and operators using nonparametric tests. Results: There were 164 samples assessed (Jamshidi n = 69, OnControl, same site as aspirate n = 48, OnControl, separate site from aspirate n = 47). The assessable and total length were similar between the Jamshidi and OnControl techniques, with increased crush artefact observed with the OnControl drill ( P < 0.001). Using a separate puncture site for trephine collection and aspirate did not reduce the artefact seen with the OnControl system ( P = 0.274). Smaller samples ( P < 0.001) and an increase in crushed ( P = 0.009) and connective tissue ( P = 0.002) were seen in trephines obtained by nonlaboratory‐based trainees, regardless of the needle used or their stage of training, compared to laboratory trainees. Conclusions: Trephines obtained by either method had similar assessable areas. The OnControl system wasAbstract: Introduction: Bone marrow biopsies are a key diagnostic and monitoring intervention in haematology with manual bone marrow techniques the established method of choice. Powered biopsy devices are now available, but are not widely used in haematology. This study compared the quality of bone marrow trephines obtained with the Jamshidi needle and OnControl powered drill system. Methods: Retrospective analysis was undertaken on trephine samples prior to and after implementation of the OnControl drill system. Trephine size and quality were assessed independently by three pathologists and compared between techniques and operators using nonparametric tests. Results: There were 164 samples assessed (Jamshidi n = 69, OnControl, same site as aspirate n = 48, OnControl, separate site from aspirate n = 47). The assessable and total length were similar between the Jamshidi and OnControl techniques, with increased crush artefact observed with the OnControl drill ( P < 0.001). Using a separate puncture site for trephine collection and aspirate did not reduce the artefact seen with the OnControl system ( P = 0.274). Smaller samples ( P < 0.001) and an increase in crushed ( P = 0.009) and connective tissue ( P = 0.002) were seen in trephines obtained by nonlaboratory‐based trainees, regardless of the needle used or their stage of training, compared to laboratory trainees. Conclusions: Trephines obtained by either method had similar assessable areas. The OnControl system was associated with more artefact, a finding in line with previous studies. There was no improvement by sampling the trephine from a separate site to the aspirate. Laboratory‐based trainees who reviewed marrow morphology produced trephines with better assessable length than those not based in the laboratory. … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 41:Number 3(2019:Jun.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 41:Number 3(2019:Jun.)
- Issue Display:
- Volume 41, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2019-0041-0003-0000
- Page Start:
- 373
- Page End:
- 379
- Publication Date:
- 2019-02-19
- Subjects:
- bone marrow biopsy -- Jamshidi needle -- OnControl bone marrow system -- powered biopsy -- quality
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12984 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16581.xml