Improvement of wide‐area damping controller subject to actuator saturation: a dynamic anti‐windup approach. Issue 9 (21st March 2018)
- Record Type:
- Journal Article
- Title:
- Improvement of wide‐area damping controller subject to actuator saturation: a dynamic anti‐windup approach. Issue 9 (21st March 2018)
- Main Title:
- Improvement of wide‐area damping controller subject to actuator saturation: a dynamic anti‐windup approach
- Authors:
- Fang, Jiakun
Yao, Wei
Chen, Zhe
Wen, Jinyu
Su, Chi
Cheng, Shijie - Abstract:
- Abstract : This study presents results on a dynamic anti‐windup compensator (DAWC) for the flexible AC transmission system‐based wide‐area damping controller (WADC). A systematic design approach of the DAWC is proposed following a typical two‐step design procedure. First, a third‐order WADC is designed for a 10‐machine, 39‐bus power system reinforced with a static synchronous compensator to damp the critical inter‐area modes by employing appropriate global signal measurements. The full‐order DAWC design method is applied to improve the dynamic performance of the saturated WADC. The robustness of the DAWC can cover a wide range of the operating conditions. Comparative studies on static AW and DAWC have been carried out on both the numerical simulation and experimental platform. Both simulation and experimental results demonstrate the improved performances of the DAWC.
- Is Part Of:
- IET generation, transmission & distribution. Volume 12:Issue 9(2018)
- Journal:
- IET generation, transmission & distribution
- Issue:
- Volume 12:Issue 9(2018)
- Issue Display:
- Volume 12, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 12
- Issue:
- 9
- Issue Sort Value:
- 2018-0012-0009-0000
- Page Start:
- 2115
- Page End:
- 2123
- Publication Date:
- 2018-03-21
- Subjects:
- flexible AC transmission systems -- power system stability
wide‐area damping controller -- actuator saturations -- dynamic AW approach -- dynamic antiwindup compensator -- flexible AC transmission system -- DAWC -- FACTS‐based WADC -- systematic design approach -- two‐step design procedure -- third‐order WADC -- 10‐machine power system -- 39‐bus power system -- static synchronous compensator -- critical inter‐area mode damping -- global signal measurements -- full‐order DAWC design method -- saturated WADC -- static AW -- numerical simulation
Electric power production -- Periodicals
Electric power transmission -- Periodicals
Electric power distribution -- Periodicals
621.3105 - Journal URLs:
- http://digital-library.theiet.org/content/journals/iet-gtd ↗
http://ieeexplore.ieee.org/servlet/opac?punumber=4082359 ↗
http://www.ietdl.org/IET-GTD ↗
https://ietresearch.onlinelibrary.wiley.com/journal/17518695 ↗
http://www.theiet.org/ ↗ - DOI:
- 10.1049/iet-gtd.2017.1032 ↗
- Languages:
- English
- ISSNs:
- 1751-8687
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4363.252540
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: