Raman measurements using a field‐widened spatial heterodyne Raman spectrometer. (28th July 2019)
- Record Type:
- Journal Article
- Title:
- Raman measurements using a field‐widened spatial heterodyne Raman spectrometer. (28th July 2019)
- Main Title:
- Raman measurements using a field‐widened spatial heterodyne Raman spectrometer
- Authors:
- Qiu, Jun
Qi, Xiangdong
Li, Xiaotian
Xu, Wenhui
Zhao, Meihong
Tang, Yuguo
Cheng, Yixue
Li, Wenhao
Jirigalantu,
Bayinheshig, - Abstract:
- Abstract: Spatial heterodyne Raman spectroscopy has become a useful spectroscopic detection technique that is particularly suitable for Raman measurements. This method uses the Fourier transform of the interferogram imaged on the detector by stationary diffraction gratings. Spatial heterodyne Raman spectroscopy has the same characteristic of conventional Fourier‐transform spectroscopy, which is that the field of view is limited. We propose a two‐dimensional spatial heterodyne Raman spectrometer (SHRS) that uses a field widening prism to effectively increase the throughput or sensitivity without sacrificing the spectral resolution for Raman measurements while broadening the bandpass. The signal‐to‐noise ratio is measured under different integrations or laser powers and shows that the system exhibits good stability and fair repeatability. Raman spectra obtained from the field‐widened SHRS and a commercialized Raman instrument are compared, and the field‐widened SHRS and the SHRS using the same instrumental parameters without field widening are also compared. A higher signal‐to‐noise ratio can be achieved using the field‐widened SHRS. In our measurements, the field‐widened SHRS can be operated under the slightly more complex conditions required for wide‐field measurements with short integration times and low laser power. Raman spectra of a pure inorganic target or a target contained in glass and a plastic bottle are observed. A sulfate is investigated in two states: solid saltAbstract: Spatial heterodyne Raman spectroscopy has become a useful spectroscopic detection technique that is particularly suitable for Raman measurements. This method uses the Fourier transform of the interferogram imaged on the detector by stationary diffraction gratings. Spatial heterodyne Raman spectroscopy has the same characteristic of conventional Fourier‐transform spectroscopy, which is that the field of view is limited. We propose a two‐dimensional spatial heterodyne Raman spectrometer (SHRS) that uses a field widening prism to effectively increase the throughput or sensitivity without sacrificing the spectral resolution for Raman measurements while broadening the bandpass. The signal‐to‐noise ratio is measured under different integrations or laser powers and shows that the system exhibits good stability and fair repeatability. Raman spectra obtained from the field‐widened SHRS and a commercialized Raman instrument are compared, and the field‐widened SHRS and the SHRS using the same instrumental parameters without field widening are also compared. A higher signal‐to‐noise ratio can be achieved using the field‐widened SHRS. In our measurements, the field‐widened SHRS can be operated under the slightly more complex conditions required for wide‐field measurements with short integration times and low laser power. Raman spectra of a pure inorganic target or a target contained in glass and a plastic bottle are observed. A sulfate is investigated in two states: solid salt and aqueous solution. Several mixture liquids, mixture solids, minerals, and anti‐Stokes Raman shifts are also investigated. The results show that the field‐widened SHRS exhibits a good performance to successfully perform wide‐field Raman measurements. Abstract : We propose a two‐dimensional spatial heterodyne Raman spectrometer (SHRS) that uses a field‐widening prism to effectively increase the throughput or sensitivity without sacrificing the spectral resolution while broadening the bandpass. Raman spectra obtained from the field‐widened SHRS and a commercialized Raman instrument are compared, and the field‐widened SHRS and the no‐field‐widened SHRS are also compared. The results of Raman measurements show that the field‐widened SHRS exhibits a good performance to successfully perform wide‐field Raman measurements. … (more)
- Is Part Of:
- Journal of Raman spectroscopy. Volume 50:Number 10(2019)
- Journal:
- Journal of Raman spectroscopy
- Issue:
- Volume 50:Number 10(2019)
- Issue Display:
- Volume 50, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 50
- Issue:
- 10
- Issue Sort Value:
- 2019-0050-0010-0000
- Page Start:
- 1602
- Page End:
- 1613
- Publication Date:
- 2019-07-28
- Subjects:
- Raman spectroscopy -- spatial heterodyne spectrometer -- field widening -- Fourier transform
Raman spectroscopy -- Periodicals
535.846 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jrs.5659 ↗
- Languages:
- English
- ISSNs:
- 0377-0486
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5045.600000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16613.xml