Single‐sided NMR to estimate morphological parameters of the trabecular bone structure. Issue 6 (22nd December 2020)
- Record Type:
- Journal Article
- Title:
- Single‐sided NMR to estimate morphological parameters of the trabecular bone structure. Issue 6 (22nd December 2020)
- Main Title:
- Single‐sided NMR to estimate morphological parameters of the trabecular bone structure
- Authors:
- Barbieri, Marco
Fantazzini, Paola
Bortolotti, Villiam
Baruffaldi, Fabio
Festa, Anna
Manners, David N.
Testa, Claudia
Brizi, Leonardo - Abstract:
- Abstract : Purpose: Single‐sided 1 H‐NMR is proposed for the estimation of morphological parameters of trabecular bone, and potentially the detection of pathophysiological alterations of bone structure. In this study, a new methodology was used to estimate such parameters without using an external reference signal, and to study intratrabecular and intertrabecular porosities, with a view to eventually scanning patients. Methods: Animal trabecular bone samples were analyzed by a single‐sided device. The Carr‐Purcell‐Meiboom‐Gill sequence of 1 H nuclei of fluids, including marrow, confined inside the bone, was analyzed by quasi‐continuous T2 distributions and separated into two 1 H pools: short and long T2 components. The NMR parameters were estimated using models of trabecular bone structure, and compared with the corresponding micro‐CT. Results: Without any further assumptions, the internal reference parameter (short T2 signal intensity fraction) enabled prediction of the micro‐CT parameters BV/TV (volume of the trabeculae/total sample volume) and BS/TV (external surface of the trabeculae/total sample volume) with linear correlation coefficient >0.80. The assignment of the two pools to intratrabecular and intertrabecular components yielded an estimate of average intratrabecular porosity (33 ± 5)%. Using the proposed models, the NMR‐estimated BV/TV and BS/TV were found to be linearly related to the corresponding micro‐CT values with high correlation (>0.90 for BV/TV; >0.80 forAbstract : Purpose: Single‐sided 1 H‐NMR is proposed for the estimation of morphological parameters of trabecular bone, and potentially the detection of pathophysiological alterations of bone structure. In this study, a new methodology was used to estimate such parameters without using an external reference signal, and to study intratrabecular and intertrabecular porosities, with a view to eventually scanning patients. Methods: Animal trabecular bone samples were analyzed by a single‐sided device. The Carr‐Purcell‐Meiboom‐Gill sequence of 1 H nuclei of fluids, including marrow, confined inside the bone, was analyzed by quasi‐continuous T2 distributions and separated into two 1 H pools: short and long T2 components. The NMR parameters were estimated using models of trabecular bone structure, and compared with the corresponding micro‐CT. Results: Without any further assumptions, the internal reference parameter (short T2 signal intensity fraction) enabled prediction of the micro‐CT parameters BV/TV (volume of the trabeculae/total sample volume) and BS/TV (external surface of the trabeculae/total sample volume) with linear correlation coefficient >0.80. The assignment of the two pools to intratrabecular and intertrabecular components yielded an estimate of average intratrabecular porosity (33 ± 5)%. Using the proposed models, the NMR‐estimated BV/TV and BS/TV were found to be linearly related to the corresponding micro‐CT values with high correlation (>0.90 for BV/TV; >0.80 for BS/TV) and agreement coefficients. Conclusion: Low‐field, low‐cost portable devices that rely on intrinsic magnetic field gradients and do not use ionizing radiation are viable tools for in vitro preclinical studies of pathophysiological structural alterations of trabecular bone. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 6(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 6(2021)
- Issue Display:
- Volume 85, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 6
- Issue Sort Value:
- 2021-0085-0006-0000
- Page Start:
- 3353
- Page End:
- 3369
- Publication Date:
- 2020-12-22
- Subjects:
- bone quality -- intratrabecular porosity -- morphological parameters -- single‐sided portable NMR -- trabecular bone
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28648 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16574.xml