Horizontal deformation of skeletal muscle thick sections visualised by confocal microscopy. (24th November 2020)
- Record Type:
- Journal Article
- Title:
- Horizontal deformation of skeletal muscle thick sections visualised by confocal microscopy. (24th November 2020)
- Main Title:
- Horizontal deformation of skeletal muscle thick sections visualised by confocal microscopy
- Authors:
- Umek, Nejc
Janáček, Jiří
Cvetko, Erika
Eržen, Ida - Abstract:
- Abstract: Certain morphological parameters of the skeletal muscle tissue can be better understood via 3D considerations. Fluorescent confocal microscopy of thick tissue sections is a well‐established method for visualising and measuring skeletal muscle fibres and surrounding capillaries in 3D. However, thick tissue sections are prone to deformations which may significantly influence some stereological and morphometric results like muscle fibre diameter and capillary length, but not dimensionless parameters like object number and Euler‐Poincaré characteristics. To better understand this phenomenon, we studied the horizontal deformation of thick (100 µm) transverse skeletal muscle sections, by comparing the muscle fibre diameters measured on thick sections to muscle fibre diameters measured on thin (10 µm) sections of the same sample. Diameter changes were further correlated with shrinkage in the Z direction (axial shrinkage) and deviation of the muscle fibre preferential axis from the Z ‐axis. We showed that the thick sections dilated in horizontal and shrunk in Z direction, and that the magnitude of horizontal dilation was associated with the magnitude of shrinkage in the Z direction. The latter was more pronounced in transversely than obliquely cut tissue sections. The results emphasise that even when shrinkage in the Z direction can be corrected using calibration, it is important to optimise histological protocols to minimise the Z ‐axis collapse that could causeAbstract: Certain morphological parameters of the skeletal muscle tissue can be better understood via 3D considerations. Fluorescent confocal microscopy of thick tissue sections is a well‐established method for visualising and measuring skeletal muscle fibres and surrounding capillaries in 3D. However, thick tissue sections are prone to deformations which may significantly influence some stereological and morphometric results like muscle fibre diameter and capillary length, but not dimensionless parameters like object number and Euler‐Poincaré characteristics. To better understand this phenomenon, we studied the horizontal deformation of thick (100 µm) transverse skeletal muscle sections, by comparing the muscle fibre diameters measured on thick sections to muscle fibre diameters measured on thin (10 µm) sections of the same sample. Diameter changes were further correlated with shrinkage in the Z direction (axial shrinkage) and deviation of the muscle fibre preferential axis from the Z ‐axis. We showed that the thick sections dilated in horizontal and shrunk in Z direction, and that the magnitude of horizontal dilation was associated with the magnitude of shrinkage in the Z direction. The latter was more pronounced in transversely than obliquely cut tissue sections. The results emphasise that even when shrinkage in the Z direction can be corrected using calibration, it is important to optimise histological protocols to minimise the Z ‐axis collapse that could cause horizontal dilation. Lay description: In skeletal muscle research, 3D analysis is especially important for studying the microvasculature. Laser scanning confocal microscopy of skeletal muscle thick tissue sections is a well‐established method for visualising and measuring skeletal muscle fibres and surrounding capillaries in 3D. However, such sections are prone to deformations which may significantly influence the study results. To better understand this phenomenon, we studied the horizontal deformation of thick transverse skeletal muscle sections. We compared the average muscle fibre diameters measured on thick skeletal muscle sections, thin fixed skeletal muscle sections and immunohistochemically stained thin skeletal muscle sections with the muscle fibre diameters measured on thin native skeletal muscle sections of the same sample, with the latter condition serving as the standard diameters (ie the control condition). We further studied the association among muscle fibre diameter changes, shrinkage of the thick skeletal muscle sections in the Z direction and their sectioning angle. We showed that the thick skeletal muscle sections dilated in the horizontal direction and shrunk in the Z direction, and that the magnitude of horizontal dilation was associated with the magnitude of shrinkage in Z direction. The shrinkage in the Z direction was more pronounced in transversely than obliquely cut tissue sections. These results emphasise that even when shrinkage in the Z direction can be corrected using Z ‐axis calibration, it is very important to optimise histological protocols to minimise the Z ‐axis collapse that could cause horizontal dilation in order to enhance the integrity of study results. … (more)
- Is Part Of:
- Journal of microscopy. Volume 282:Part 2(2021)
- Journal:
- Journal of microscopy
- Issue:
- Volume 282:Part 2(2021)
- Issue Display:
- Volume 282, Issue 2, Part 2 (2021)
- Year:
- 2021
- Volume:
- 282
- Issue:
- 2
- Part:
- 2
- Issue Sort Value:
- 2021-0282-0002-0002
- Page Start:
- 113
- Page End:
- 122
- Publication Date:
- 2020-11-24
- Subjects:
- 3D -- fibre diameter -- horizontal dilation -- sample deformation -- shrinkage in Z direction
Microscopy -- Periodicals
502.82 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jmi&close=1997#C1997 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jmi.12985 ↗
- Languages:
- English
- ISSNs:
- 0022-2720
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5019.695000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16543.xml