Safety of same‐day discharge after uncomplicated, minimalist transcatheter aortic valve replacement in the COVID‐19 era. Issue 5 (31st December 2020)
- Record Type:
- Journal Article
- Title:
- Safety of same‐day discharge after uncomplicated, minimalist transcatheter aortic valve replacement in the COVID‐19 era. Issue 5 (31st December 2020)
- Main Title:
- Safety of same‐day discharge after uncomplicated, minimalist transcatheter aortic valve replacement in the COVID‐19 era
- Authors:
- Perdoncin, Emily
Greenbaum, Adam B.
Grubb, Kendra J.
Babaliaros, Vasilis C.
Keegan, Patricia
Ceretto‐Clark, Brendan
Wei, Jane
Guyton, Robert A.
Paone, Gaetano
Byku, Isida
Gleason, Patrick T.
Biven, Kelby
Mathew, Preethy
Mortorano, Cecilia
Inci, Errol K.
Faaborg‐Andersen, Christian
Mitchell, Rae
Devireddy, Chandan M. - Abstract:
- Abstract: Objectives: We sought to evaluate the safety, efficacy and feasibility of same‐day discharge after uncomplicated, minimalist TAVR. Background: At the start of the COVID‐19 pandemic, we created a same‐day discharge (SDD) pathway after conscious sedation, transfemoral (minimalist) TAVR to help minimize risk of viral transmission and conserve hospital resources. Studies support that next‐day discharge (NDD) for carefully selected patients following minimalist TAVR is safe and feasible. There is a paucity of data regarding the safety of SDD after TAVR. Methods: In‐hospital and 30 day outcomes of consecutive patients meeting pre‐specified criteria for SDD after minimalist TAVR at our institution between March and July of 2020 were reviewed. Outcomes were compared to a NDD cohort from July 2018 through July 2020 that would have met SDD criteria. Primary endpoints were mortality, delayed pacemaker placement, stroke and cardiovascular readmission at 30 days. Results: Twenty nine patients were discharged via the SDD pathway after TAVR. 128 prior NDD patients were identified who met all criteria for SDD. The STS scores were similar between the two groups (SDD 2.6% ±1.5 vs. NDD 2.3% ± 1.2). There were no deaths at 30 days in either group. There was no significant difference in delayed pacemaker placement (SDD 0% vs. NDD 0.8%, p > .99) or cardiovascular readmission (SDD 0% vs. NDD 5.5%, p = .35) at 30 days. Conclusions: Same day discharge following uncomplicated, minimalistAbstract: Objectives: We sought to evaluate the safety, efficacy and feasibility of same‐day discharge after uncomplicated, minimalist TAVR. Background: At the start of the COVID‐19 pandemic, we created a same‐day discharge (SDD) pathway after conscious sedation, transfemoral (minimalist) TAVR to help minimize risk of viral transmission and conserve hospital resources. Studies support that next‐day discharge (NDD) for carefully selected patients following minimalist TAVR is safe and feasible. There is a paucity of data regarding the safety of SDD after TAVR. Methods: In‐hospital and 30 day outcomes of consecutive patients meeting pre‐specified criteria for SDD after minimalist TAVR at our institution between March and July of 2020 were reviewed. Outcomes were compared to a NDD cohort from July 2018 through July 2020 that would have met SDD criteria. Primary endpoints were mortality, delayed pacemaker placement, stroke and cardiovascular readmission at 30 days. Results: Twenty nine patients were discharged via the SDD pathway after TAVR. 128 prior NDD patients were identified who met all criteria for SDD. The STS scores were similar between the two groups (SDD 2.6% ±1.5 vs. NDD 2.3% ± 1.2). There were no deaths at 30 days in either group. There was no significant difference in delayed pacemaker placement (SDD 0% vs. NDD 0.8%, p > .99) or cardiovascular readmission (SDD 0% vs. NDD 5.5%, p = .35) at 30 days. Conclusions: Same day discharge following uncomplicated, minimalist TAVR in selected patients appears to be safe, achieving similar 30 day outcomes as a cohort of next day discharge patients. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 97:Issue 5(2021)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 97:Issue 5(2021)
- Issue Display:
- Volume 97, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 97
- Issue:
- 5
- Issue Sort Value:
- 2021-0097-0005-0000
- Page Start:
- 940
- Page End:
- 947
- Publication Date:
- 2020-12-31
- Subjects:
- aortic valve replacement -- expedited discharge -- TAVR
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29453 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16549.xml