Heating of hip joint implants in MRI: The combined effect of RF and switched‐gradient fields. Issue 6 (22nd January 2021)
- Record Type:
- Journal Article
- Title:
- Heating of hip joint implants in MRI: The combined effect of RF and switched‐gradient fields. Issue 6 (22nd January 2021)
- Main Title:
- Heating of hip joint implants in MRI: The combined effect of RF and switched‐gradient fields
- Authors:
- Arduino, Alessandro
Zanovello, Umberto
Hand, Jeff
Zilberti, Luca
Brühl, Rüdiger
Chiampi, Mario
Bottauscio, Oriano - Abstract:
- Abstract : Purpose: To investigate how the simultaneous exposure to gradient and RF fields affects the temperature rise in patients with a metallic hip prosthesis during an MRI session. Methods: In silico analysis was performed with an anatomically realistic human model with CoCrMo hip implant in 12 imaging positions. The analysis was performed at 1.5 T and 3 T, considering four clinical sequences: turbo spin‐echo, EPI, gradient‐echo, and true fast imaging sequence with steady precession. The exposure to gradient and RF fields was evaluated separately and superposed, by adopting an ad hoc computational algorithm. Temperature increase within the body, rather than specific absorption rate, was used as a safety metric. Results: With the exception of gradient‐echo, all investigated sequences produced temperature increases higher than 1 K after 360 seconds, at least for one body position. In general, RF‐induced heating dominates the turbo spin‐echo sequence, whereas gradient‐induced heating prevails with EPI; the situation with fast imaging sequence with steady precession is more diversified. The RF effects are enhanced when the implant is within the RF coil, whereas the effects of gradient fields are maximized if the prosthesis is outside the imaging region. Cases for which temperature‐increase thresholds were exceeded were identified, together with the corresponding amount of tissue mass involved and the exposure time needed to reach these limits. Conclusion: The analysisAbstract : Purpose: To investigate how the simultaneous exposure to gradient and RF fields affects the temperature rise in patients with a metallic hip prosthesis during an MRI session. Methods: In silico analysis was performed with an anatomically realistic human model with CoCrMo hip implant in 12 imaging positions. The analysis was performed at 1.5 T and 3 T, considering four clinical sequences: turbo spin‐echo, EPI, gradient‐echo, and true fast imaging sequence with steady precession. The exposure to gradient and RF fields was evaluated separately and superposed, by adopting an ad hoc computational algorithm. Temperature increase within the body, rather than specific absorption rate, was used as a safety metric. Results: With the exception of gradient‐echo, all investigated sequences produced temperature increases higher than 1 K after 360 seconds, at least for one body position. In general, RF‐induced heating dominates the turbo spin‐echo sequence, whereas gradient‐induced heating prevails with EPI; the situation with fast imaging sequence with steady precession is more diversified. The RF effects are enhanced when the implant is within the RF coil, whereas the effects of gradient fields are maximized if the prosthesis is outside the imaging region. Cases for which temperature‐increase thresholds were exceeded were identified, together with the corresponding amount of tissue mass involved and the exposure time needed to reach these limits. Conclusion: The analysis confirms that risky situations may occur when a patient carrying a hip implant undergoes an MRI exam and that, in some cases, the gradient field heating may be significant. In general, exclusion criteria only based on whole‐body specific absorption rate may not be sufficient to ensure patients' safety. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 6(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 6(2021)
- Issue Display:
- Volume 85, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 6
- Issue Sort Value:
- 2021-0085-0006-0000
- Page Start:
- 3447
- Page End:
- 3462
- Publication Date:
- 2021-01-22
- Subjects:
- gradient coil heating -- hip prosthesis -- MRI safety -- numerical simulation -- radiofrequency heating
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28666 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16574.xml