Outcome of durable mechanical circulatory support devices in a tertiary care hospital in Saudi Arabia. (26th April 2021)
- Record Type:
- Journal Article
- Title:
- Outcome of durable mechanical circulatory support devices in a tertiary care hospital in Saudi Arabia. (26th April 2021)
- Main Title:
- Outcome of durable mechanical circulatory support devices in a tertiary care hospital in Saudi Arabia
- Authors:
- Laimoud, M
Saad, E
Alburaiki, J
Alibrahim, M
Alsomali, A
Alhussein, M
Khaliel, F - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Heart failure (HF) remains a significant cause of morbidity and mortality. Heart transplantation is the gold standard treatment for end stage heart failure. Durable mechanical circulatory support devices became a modality of treatment as bridge to transplantation or destination therapy because of the shortage of donor hearts. Objective: To report the experience of durable mechanical circulatory devices in our tertiary care hospital as compared with the report of the International Society of Mechanically Assisted Circulatory Support (IMACS) registry. Results: Between 2013 until December 2019, 73 durable mechanical circulatory support devices were implanted. Mean age 41.36 ±14.1 years and 83.6% of them were male. Etiology: 52.1% of the patients had dilated cardiomyopathy while 34.2% had ischemic cardiomyopathy. Age distribution: 45.2% of the patients were in the age group of 30-49 years while 32.9% were in the age group of 50-69 years. No devices were inserted in patients within the age group ≥70 years. Left ventricular assist devices with continuous pump flow accounted for 82.2% of implanted devices while biventricular support accounted for 15.1%. Total artificial hearts were implanted in 2.7% of the patients. INTERMACS categories at the time of implantation: 20.6% of patients were in INTERMACS I, INTERMACS II 38.4%, INTERMACS III 22%, INTERMACS IV17.6% while only 1.4% were INTERMACS V. DeviceAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Heart failure (HF) remains a significant cause of morbidity and mortality. Heart transplantation is the gold standard treatment for end stage heart failure. Durable mechanical circulatory support devices became a modality of treatment as bridge to transplantation or destination therapy because of the shortage of donor hearts. Objective: To report the experience of durable mechanical circulatory devices in our tertiary care hospital as compared with the report of the International Society of Mechanically Assisted Circulatory Support (IMACS) registry. Results: Between 2013 until December 2019, 73 durable mechanical circulatory support devices were implanted. Mean age 41.36 ±14.1 years and 83.6% of them were male. Etiology: 52.1% of the patients had dilated cardiomyopathy while 34.2% had ischemic cardiomyopathy. Age distribution: 45.2% of the patients were in the age group of 30-49 years while 32.9% were in the age group of 50-69 years. No devices were inserted in patients within the age group ≥70 years. Left ventricular assist devices with continuous pump flow accounted for 82.2% of implanted devices while biventricular support accounted for 15.1%. Total artificial hearts were implanted in 2.7% of the patients. INTERMACS categories at the time of implantation: 20.6% of patients were in INTERMACS I, INTERMACS II 38.4%, INTERMACS III 22%, INTERMACS IV17.6% while only 1.4% were INTERMACS V. Device strategy: 73.9% of devices were implanted as a bridge to candidacy for transplantation, 15.1 % were implanted as a bridge to cardiac recover, 8.2% were listed to heart transplantation while only 2.7% were left for destination therapy strategy. 50.7% of patients were discharged home after fulfilling education requirements. Forty per cent of the patients underwent heart transplantation. Major adverse events: 5.4% of the patients developed major cerebrovascular strokes after device implantation. Mediastinal significant bleeding and exploration occurred in 12.3% of patients and gastrointestinal bleeding in 8.2%. Driveline infection occurred in 16.4% of patients but only 2.7% had deep wound infection requiring urgent heart transplantation. Mortality on the device was 31.5%. Conclusion: Our experience with mechanical circulatory support is similar to the reported major events and survival from the International Society of Mechanically Assisted Circulatory Support. … (more)
- Is Part Of:
- European heart journal. Volume 10(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 10(2021)Supplement 1
- Issue Display:
- Volume 10, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2021-0010-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04-26
- Subjects:
- 616.1205
- Journal URLs:
- https://academic.oup.com/ehjacc/issue ↗
http://acc.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1093/ehjacc/zuab020.156 ↗
- Languages:
- English
- ISSNs:
- 2048-8726
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16536.xml