Performance testing of dosimeters used in interventional radiology: Results from the VERIDIC project. (February 2021)
- Record Type:
- Journal Article
- Title:
- Performance testing of dosimeters used in interventional radiology: Results from the VERIDIC project. (February 2021)
- Main Title:
- Performance testing of dosimeters used in interventional radiology: Results from the VERIDIC project
- Authors:
- Kržanović, Nikola
Blideanu, Valentin
Ciraj-Bjelac, Olivera
Plagnard, Johann
Schoonjans, Werner
Živanović, Miloš
Dabin, Jérémie - Abstract:
- Abstract: Interventional procedures in radiology and cardiology are associated with high dose to the patient. Accurate dosimetry is essential and calibration of the equipment is a means to provide the necessary accuracy of dose assessment. The objective of this work is to investigate the performance of dosimeters used in interventional procedures in different standard and non-standard X-ray radiation qualities, and to investigate potential uncertainties related to dose measurements, thus improving accuracy of patient dosimetry in interventional procedures. Four new reference radiation qualities dedicated to interventional cardiology applications have been established, allowing calibration of dosimeters used in clinical conditions with appropriate traceability to primary standards. Testing of solid-state semiconductor detectors and thermoluminescent dosimeter properties, e.g. influence of photon energy, angle of incidence and dose rate, was performed in the standard and non-standard radiation qualities. Both dosimeter types showed good performance in the non-standard beams during all performance tests. Solid-state dosimeters displayed weak dependence on energy, angle of incidence and dose rate, in the range defined by the manufacturer and requirements of the international standard. Thermoluminescent dosimeters displayed excellent linearity and angular dependence. The influence of energy dependence on measurement uncertainty can be reduced if appropriate radiation quality isAbstract: Interventional procedures in radiology and cardiology are associated with high dose to the patient. Accurate dosimetry is essential and calibration of the equipment is a means to provide the necessary accuracy of dose assessment. The objective of this work is to investigate the performance of dosimeters used in interventional procedures in different standard and non-standard X-ray radiation qualities, and to investigate potential uncertainties related to dose measurements, thus improving accuracy of patient dosimetry in interventional procedures. Four new reference radiation qualities dedicated to interventional cardiology applications have been established, allowing calibration of dosimeters used in clinical conditions with appropriate traceability to primary standards. Testing of solid-state semiconductor detectors and thermoluminescent dosimeter properties, e.g. influence of photon energy, angle of incidence and dose rate, was performed in the standard and non-standard radiation qualities. Both dosimeter types showed good performance in the non-standard beams during all performance tests. Solid-state dosimeters displayed weak dependence on energy, angle of incidence and dose rate, in the range defined by the manufacturer and requirements of the international standard. Thermoluminescent dosimeters displayed excellent linearity and angular dependence. The influence of energy dependence on measurement uncertainty can be reduced if appropriate radiation quality is selected for calibration. Highlights: Interventional procedures in diagnostic radiology are not covered by standard radiation qualities. Non-standard radiation qualities were established related to clinical conditions. Behaviour of solid-state semiconductor and thermoluminescent dosimeters was tested. Measurement uncertainty in dosimetry in interventional procedures was improved. … (more)
- Is Part Of:
- Radiation measurements. Volume 141(2020:Oct.)
- Journal:
- Radiation measurements
- Issue:
- Volume 141(2020:Oct.)
- Issue Display:
- Volume 141 (2020)
- Year:
- 2020
- Volume:
- 141
- Issue Sort Value:
- 2020-0141-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Diagnostic radiology -- Dosimetry -- Interventional cardiology -- Radiation quality -- X-rays
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2021.106515 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16522.xml