Platform Session – Evoked potentials & NIOM: Use of motor evoked potentials during lateral lumbar interbody fusion reduces postoperative deficits. (May 2018)
- Record Type:
- Journal Article
- Title:
- Platform Session – Evoked potentials & NIOM: Use of motor evoked potentials during lateral lumbar interbody fusion reduces postoperative deficits. (May 2018)
- Main Title:
- Platform Session – Evoked potentials & NIOM: Use of motor evoked potentials during lateral lumbar interbody fusion reduces postoperative deficits
- Authors:
- Riley, Michael R.
Doan, Adam T.
Vogel, Richard
Scheid, Edward - Abstract:
- Abstract : Introduction: Intraoperative neurophysiological monitoring (IONM) has gained rather wide-spread acceptance as a method to mitigate risk to the lumbar plexus during Lateral Lumbar Interbody Fusion (LLIF) surgery. The most common approach to IONM involves using only electromyography (EMG) monitoring, and the rate of postoperative deficit remains unacceptably high. Other test modalities, such as transcranial electric motor-evoked potentials (tcMEPs) may be more suitable for monitoring neural integrity but have not been widely adopted during LLIF. Recent studies have begun to examine their utility in monitoring LLIF surgery with favorable results. Methods: We conducted a non-randomized, retrospective analysis of 479 LLIF procedures at a single institution over a four-year period. During the study epoch, three different IONM strategies were employed for LLIF procedures: (1) Surgeon-directed T-EMG monitoring ("SD-EMG"), (2) neurophysiologist-controlled T-EMG monitoring ("NC-EMG"), and (3) neurophysiologist-controlled T-EMG monitoring supplemented with MEP monitoring ("NC-MEP"). Patient progress notes were reviewed from the postoperative period up to 12 months after surgery. The rates of postoperative sensory or motor deficit consistent with lumbar plexopathy or peripheral nerve palsy on the surgical side were compared between the three cohorts. Results: Using the dependent measure of neurologic deficit, whether motor and/or sensory, patients with NC-MEP monitoring hadAbstract : Introduction: Intraoperative neurophysiological monitoring (IONM) has gained rather wide-spread acceptance as a method to mitigate risk to the lumbar plexus during Lateral Lumbar Interbody Fusion (LLIF) surgery. The most common approach to IONM involves using only electromyography (EMG) monitoring, and the rate of postoperative deficit remains unacceptably high. Other test modalities, such as transcranial electric motor-evoked potentials (tcMEPs) may be more suitable for monitoring neural integrity but have not been widely adopted during LLIF. Recent studies have begun to examine their utility in monitoring LLIF surgery with favorable results. Methods: We conducted a non-randomized, retrospective analysis of 479 LLIF procedures at a single institution over a four-year period. During the study epoch, three different IONM strategies were employed for LLIF procedures: (1) Surgeon-directed T-EMG monitoring ("SD-EMG"), (2) neurophysiologist-controlled T-EMG monitoring ("NC-EMG"), and (3) neurophysiologist-controlled T-EMG monitoring supplemented with MEP monitoring ("NC-MEP"). Patient progress notes were reviewed from the postoperative period up to 12 months after surgery. The rates of postoperative sensory or motor deficit consistent with lumbar plexopathy or peripheral nerve palsy on the surgical side were compared between the three cohorts. Results: Using the dependent measure of neurologic deficit, whether motor and/or sensory, patients with NC-MEP monitoring had the lowest rate of immediate postoperative deficit (22.3%), compared to NC-EMG monitoring (37.1%) and SD-EMG monitoring (40.4%). This result extended to sensory deficits consistent with lumbar plexopathy (pure motor deficits being excluded); patients with NC-MEP monitoring had the lowest rate (20.5%) compared to NC-EMG monitoring (34.3%) and SD-EMG monitoring (36.9%). Additionally, evaluation of postoperative motor deficits consistent with peripheral nerve palsy (pure sensory deficits being excluded), the NC-MEP group had the lowest rate (5.7%) of motor deficit compared to the SD-EMG (17.0%) and NC-EMG (17.1%) cohorts. Finally, when assessing only those patients whose last follow-up was greater than or equal to 12 months ( n = 251), the rate of unresolved motor deficits was significantly lower in the NC-MEP group (0.9%), as compared to NC-EMG (6.9%) and SD-EMG (11.0%). Comparison of the NC-MEP versus NC-EMG and SD-EMG groups, both independently and combined, was statistically significant (>95% confidence level) for all analyses. Conclusion: The results of the present study indicate that preservation of tcMEPs from the adductor longus, quadriceps, and tibialis anterior muscles are of paramount importance for limiting iatrogenic sensory and motor injuries during LLIF surgery. In this regard, tcMEPs appear to be the most effective modality for the prevention of both transient and permanent neurologic injury during LLIF surgery. We propose that the standard paradigm for protecting the nervous system during LLIF be adapted to include tcMEPs. … (more)
- Is Part Of:
- Clinical neurophysiology. Volume 129(2018)Supplement 1
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 129(2018)Supplement 1
- Issue Display:
- Volume 129, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 129
- Issue:
- 1
- Issue Sort Value:
- 2018-0129-0001-0000
- Page Start:
- e228
- Page End:
- Publication Date:
- 2018-05
- Subjects:
- Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2018.04.587 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16507.xml