Hilbert–Huang transform based instrumental assessment of intention tremor in multiple sclerosis. (3rd June 2015)
- Record Type:
- Journal Article
- Title:
- Hilbert–Huang transform based instrumental assessment of intention tremor in multiple sclerosis. (3rd June 2015)
- Main Title:
- Hilbert–Huang transform based instrumental assessment of intention tremor in multiple sclerosis
- Authors:
- Carpinella, Ilaria
Cattaneo, Davide
Ferrarin, Maurizio - Abstract:
- Abstract: Objective. This paper describes a method to extract upper limb intention tremor from gyroscope data, through the Hilbert–Huang transform (HHT), a technique suitable for the study of nonlinear and non-stationary processes. The aims of the study were to: (i) evaluate the method's ability to discriminate between healthy controls and MS subjects; (ii) validate the proposed procedure against clinical tremor scores assigned using Fahn's tremor rating scale (FTRS); and (iii) compare the performance of the HHT-based method with that of linear band-pass filters. Approach. HHT was applied on gyroscope data collected on 20 MS subjects and 13 healthy controls (CO) during finger-to-nose tests (FNTs) instrumented with an inertial sensor placed on the hand. The results were compared to those obtained after traditional linear filtering. The tremor amplitude was quantified with instrumental indexes (TIs) and clinical FTRS ratings. Main results. The TIs computed after HHT-based filtering discriminated between CO and MS subjects with clinically-detected intention tremor (MS_T). In particular, TIs were significantly higher in the final part of the movement (TI2 ) with respect to the first part (TI1 ), and, for all components (X, Y, Z), MS_T showed a TI2 significantly higher than in CO subjects. Moreover, the HHT detected subtle alterations not visible from clinical ratings, as TI2 (Z-component) was significantly increased in MS subjects without clinically-detected tremor (MS_NT). TheAbstract: Objective. This paper describes a method to extract upper limb intention tremor from gyroscope data, through the Hilbert–Huang transform (HHT), a technique suitable for the study of nonlinear and non-stationary processes. The aims of the study were to: (i) evaluate the method's ability to discriminate between healthy controls and MS subjects; (ii) validate the proposed procedure against clinical tremor scores assigned using Fahn's tremor rating scale (FTRS); and (iii) compare the performance of the HHT-based method with that of linear band-pass filters. Approach. HHT was applied on gyroscope data collected on 20 MS subjects and 13 healthy controls (CO) during finger-to-nose tests (FNTs) instrumented with an inertial sensor placed on the hand. The results were compared to those obtained after traditional linear filtering. The tremor amplitude was quantified with instrumental indexes (TIs) and clinical FTRS ratings. Main results. The TIs computed after HHT-based filtering discriminated between CO and MS subjects with clinically-detected intention tremor (MS_T). In particular, TIs were significantly higher in the final part of the movement (TI2 ) with respect to the first part (TI1 ), and, for all components (X, Y, Z), MS_T showed a TI2 significantly higher than in CO subjects. Moreover, the HHT detected subtle alterations not visible from clinical ratings, as TI2 (Z-component) was significantly increased in MS subjects without clinically-detected tremor (MS_NT). The method's validity was demonstrated by significant correlations between clinical FTRS scores and TI2 related to X (rs = 0.587, p = 0.006) and Y (rs = 0.682, p < 0.001) components. Contrarily, fewer differences among the groups and no correlation between instrumental and clinical indexes emerged after traditional filtering. Significance. The present results supported the use of the HHT-based procedure for a fully-automated quantitative and objective measure of intention tremor in MS, which can overcome the limitations of clinical scales and provide supplementary information about this sign. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 12:Number 4(2015:Aug.)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 12:Number 4(2015:Aug.)
- Issue Display:
- Volume 12, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 12
- Issue:
- 4
- Issue Sort Value:
- 2015-0012-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-06-03
- Subjects:
- Hilbert-Huang transform -- intention tremor -- gyroscope -- multiple sclerosis
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2560/12/4/046011 ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16489.xml