Controllable DC‐link fault current limiter augmentation with DC chopper to improve fault ride‐through of DFIG. Issue 2 (24th January 2017)
- Record Type:
- Journal Article
- Title:
- Controllable DC‐link fault current limiter augmentation with DC chopper to improve fault ride‐through of DFIG. Issue 2 (24th January 2017)
- Main Title:
- Controllable DC‐link fault current limiter augmentation with DC chopper to improve fault ride‐through of DFIG
- Authors:
- Jalilian, Amin
Naderi, Seyed Behzad
Negnevitsky, Michael
Tarafdar Hagh, Mehrdad
Muttaqi, Kashem M. - Abstract:
- Abstract : Doubly fed induction generator (DFIG) based wind turbines are sensitive to grid faults due to utilising small‐scale rotor side converter (RSC). The application of crowbar protection to improve the fault ride‐through (FRT) capability of the DFIG converts it to a squirrel cage induction generator, which makes it difficult to comply with grid codes. This study proposes an innovative DC‐link controllable fault current limiter (C‐FCL) based FRT scheme for the RSC to improve the FRT capability of the DFIG. The proposed scheme replaces the AC crowbar protection and eliminates its disadvantages. The C‐FCL does not affect the normal operation of the DFIG. By means of the proposed scheme, rotor over‐currents are successfully limited during balanced and unbalanced grid faults, even at zero grid voltage. Also, the C‐FCL prevents rotor acceleration and high torque oscillations. In this study, an analysis of the proposed approach is presented in detail. The performance of the proposed scheme is compared with the conventional crowbar protection scheme through simulation studies carried out in power system computer‐aided design/electromagnetic transients, including dc software (PSCAD/EMTDC). Moreover, the main concept of the proposed approach is validated with an experimental setup and test results are presented.
- Is Part Of:
- IET renewable power generation. Volume 11:Issue 2(2017)
- Journal:
- IET renewable power generation
- Issue:
- Volume 11:Issue 2(2017)
- Issue Display:
- Volume 11, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2017-0011-0002-0000
- Page Start:
- 313
- Page End:
- 324
- Publication Date:
- 2017-01-24
- Subjects:
- fault current limiters -- wind turbines -- asynchronous generators
controllable DC‐link fault current limiter augmentation -- DC chopper -- DFIG -- doubly fed induction generator -- wind turbines -- small‐scale rotor side converter -- fault ride‐through capability -- power system computer‐aided design -- electromagnetic transients -- dc software
Renewable energy sources -- Periodicals
333.79405 - Journal URLs:
- http://digital-library.theiet.org/content/journals/iet-rpg ↗
http://ieeexplore.ieee.org/servlet/opac?punumber=4159946 ↗
http://www.ietdl.org/IET-RPG ↗
https://ietresearch.onlinelibrary.wiley.com/journal/17521424 ↗
http://www.theiet.org/ ↗ - DOI:
- 10.1049/iet-rpg.2016.0146 ↗
- Languages:
- English
- ISSNs:
- 1752-1416
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4363.253450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16486.xml