Circuit Hemodynamics and Circuit Failure During Continuous Renal Replacement Therapy. Issue 11 (November 2019)
- Record Type:
- Journal Article
- Title:
- Circuit Hemodynamics and Circuit Failure During Continuous Renal Replacement Therapy. Issue 11 (November 2019)
- Main Title:
- Circuit Hemodynamics and Circuit Failure During Continuous Renal Replacement Therapy
- Authors:
- Sansom, Benjamin
Sriram, Shyamala
Presneill, Jeffrey
Bellomo, Rinaldo - Abstract:
- Abstract : Objectives: To study hemodynamic changes within continuous renal replacement therapy circuits and evaluate their relationship with continuous renal replacement therapy longevity. Design: Analysis of downloaded variables recorded by continuous renal replacement therapy machines during multiple episodes of clinical care. Setting: Tertiary ICU in Melbourne, Australia. Patients: Cohort of 149 ICU patients: 428 episodes of continuous renal replacement therapy. Interventions: None. Measurements and Main Results: Indices of continuous renal replacement therapy function representing 554, 991 minutes were assessed including blood flow, access pressure, effluent pressure, prefilter pressure, and return pressure. We defined three patterns of artificial kidney failure: early (⩽ 12 hr), intermediate (> 12–24 hr), and late (> 24 hr) in 35%, 31%, and 34% of circuits, respectively. Mean access pressure in late artificial kidney failure was 7.5 mm Hg (7.1–7.9 mm Hg) less negative than early failing circuits and pressures demonstrated lower variability in such late failing circuits. Access dysfunction, defined as access pressure less than or equal to –200 mm Hg occurred in the first 4 hours in 118 circuits (27%) which had a shorter (median [interquartile range]) life at 12.9 hr [5.5–21.3 hr]) hours than access dysfunction-free circuits (18.8 hr [10.1–33.4 hr]; p < 0.0001). Multivariate analysis found the first occurrence of access dysfunction (as a time-varying covariate) wasAbstract : Objectives: To study hemodynamic changes within continuous renal replacement therapy circuits and evaluate their relationship with continuous renal replacement therapy longevity. Design: Analysis of downloaded variables recorded by continuous renal replacement therapy machines during multiple episodes of clinical care. Setting: Tertiary ICU in Melbourne, Australia. Patients: Cohort of 149 ICU patients: 428 episodes of continuous renal replacement therapy. Interventions: None. Measurements and Main Results: Indices of continuous renal replacement therapy function representing 554, 991 minutes were assessed including blood flow, access pressure, effluent pressure, prefilter pressure, and return pressure. We defined three patterns of artificial kidney failure: early (⩽ 12 hr), intermediate (> 12–24 hr), and late (> 24 hr) in 35%, 31%, and 34% of circuits, respectively. Mean access pressure in late artificial kidney failure was 7.5 mm Hg (7.1–7.9 mm Hg) less negative than early failing circuits and pressures demonstrated lower variability in such late failing circuits. Access dysfunction, defined as access pressure less than or equal to –200 mm Hg occurred in the first 4 hours in 118 circuits (27%) which had a shorter (median [interquartile range]) life at 12.9 hr [5.5–21.3 hr]) hours than access dysfunction-free circuits (18.8 hr [10.1–33.4 hr]; p < 0.0001). Multivariate analysis found the first occurrence of access dysfunction (as a time-varying covariate) was independently associated with increased hazard of subsequent failure (hazard ratio, 1.75; 1.36–2.26). Classification and regression tree analysis of summary pressure indices in the first 2 hours confirmed minimum access pressure to be a significant predictor, as well as indices of transmembrane pressure and return pressure. A pressure-based predictor correctly identified early and late failing circuits (86.2% and 93.6% specificity, respectively). Conclusions: Access dysfunction is a predictor of continuous renal replacement therapy circuit failure. Future monitoring of continuous renal replacement therapy hemodynamics may facilitate remedial actions to improve circuit function. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 47:Issue 11(2019)
- Journal:
- Critical care medicine
- Issue:
- Volume 47:Issue 11(2019)
- Issue Display:
- Volume 47, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 11
- Issue Sort Value:
- 2019-0047-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11
- Subjects:
- continuous renal replacement therapy -- hemodiafiltration -- intensive care -- medical informatics -- observational study
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000003958 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16498.xml