Wireless wearable range‐of‐motion sensor system for upper and lower extremity joints: a validation study. Issue 1 (10th February 2015)
- Record Type:
- Journal Article
- Title:
- Wireless wearable range‐of‐motion sensor system for upper and lower extremity joints: a validation study. Issue 1 (10th February 2015)
- Main Title:
- Wireless wearable range‐of‐motion sensor system for upper and lower extremity joints: a validation study
- Authors:
- Kumar, Yogaprakash
Yen, Shih‐Cheng
Tay, Arthur
Lee, Wangwei
Gao, Fan
Zhao, Ziyi
Li, Jingze
Hon, Benjamin
Tian‐Ma Xu, Tim
Cheong, Angela
Koh, Karen
Ng, Yee‐Sien
Chew, Effie
Koh, Gerald - Abstract:
- Abstract : Range‐of‐motion (ROM) assessment is a critical assessment tool during the rehabilitation process. The conventional approach uses the goniometer which remains the most reliable instrument but it is usually time‐consuming and subject to both intra‐ and inter‐therapist measurement errors. An automated wireless wearable sensor system for the measurement of ROM has previously been developed by the current authors. Presented is the correlation and accuracy of the automated wireless wearable sensor system against a goniometer in measuring ROM in the major joints of upper (UEs) and lower extremities (LEs) in 19 healthy subjects and 20 newly disabled inpatients through intra (same) subject comparison of ROM assessments between the sensor system against goniometer measurements by physical therapists. In healthy subjects, ROM measurements using the new sensor system were highly correlated with goniometry, with 95% of differences < 20° and 10° for most movements in major joints of UE and LE, respectively. Among inpatients undergoing rehabilitation, ROM measurements using the new sensor system were also highly correlated with goniometry, with 95% of the differences being < 20° and 25° for most movements in the major joints of UE and LE, respectively.
- Is Part Of:
- Healthcare technology letters. Volume 2:Issue 1(2015)
- Journal:
- Healthcare technology letters
- Issue:
- Volume 2:Issue 1(2015)
- Issue Display:
- Volume 2, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 2
- Issue:
- 1
- Issue Sort Value:
- 2015-0002-0001-0000
- Page Start:
- 12
- Page End:
- 17
- Publication Date:
- 2015-02-10
- Subjects:
- wireless sensor networks -- biomechanics -- motion measurement -- patient rehabilitation -- goniometers -- biomedical equipment
goniometer measurements -- rehabilitation process -- range‐of‐motion assessment -- lower extremity joints -- upper extremity joints -- wireless wearable range‐of‐motion sensor system
Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://digital-library.theiet.org/content/journals/htl ↗
http://ieeexplore.ieee.org/Xplore/home.jsp ↗ - DOI:
- 10.1049/htl.2014.0100 ↗
- Languages:
- English
- ISSNs:
- 2053-3713
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4275.248050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16487.xml