Histologic retrieval rate of a newly designed side‐bevelled 20G needle for EUS‐guided tissue acquisition of solid pancreatic lesions. Issue 1 (1st February 2019)
- Record Type:
- Journal Article
- Title:
- Histologic retrieval rate of a newly designed side‐bevelled 20G needle for EUS‐guided tissue acquisition of solid pancreatic lesions. Issue 1 (1st February 2019)
- Main Title:
- Histologic retrieval rate of a newly designed side‐bevelled 20G needle for EUS‐guided tissue acquisition of solid pancreatic lesions
- Authors:
- Armellini, Elia
Manfrin, Erminia
Trisolini, Elena
Andorno, Silvano
Ballarè, Marco
Bernardoni, Laura
Boldorini, Renzo Luciano
Gabbrielli, Armando
Frulloni, Luca
Larghi, Alberto
Occhipinti, Pietro
Scarpa, Aldo
Crinò, Stefano Francesco - Abstract:
- Abstract : Background: Innovative approaches to improve diagnostic yield of endoscopic ultrasound‐guided tissue acquisition (EUS‐TA) have focused on needle design with development of fine‐needle biopsy (FNB) needles with microcore‐acquisition technology. Recently, a 20‐gauge (20G) antegrade‐cutting‐side‐bevelled biopsy needle (ProCore®) was developed for EUS‐TA, but data about its diagnostic performance and histological capability are scant. Objectives: We assessed the diagnostic performance and histologic retrieval rate of a new 20G antegrade‐cutting‐side‐bevelled biopsy needle compared with a 22G reverse‐side‐bevelled needle for EUS sampling of solid pancreatic lesions. Patients and methods: A retrospective analysis of 238 consecutively collected patients who underwent EUS‐TA using a 20G or a 22G ProCore® needle, without rapid on‐site evaluation (ROSE), was conducted at two centres. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Histologic tissue retrieval was evaluated applying a scoring system for each case. Results: Sensitivity and specificity were estimated as 98.4–100% in the 20G‐, and 94.9–100% in the 22G‐needle groups, respectively ( p > 0.99). The 20G procured more histologic‐grade tissues (92.6% vs 49.5%, p < 0.0001) achieved by a lower number of passes (2.64 vs 3.44, p < 0.0001) compared to the 22G. Conclusions: Both side‐bevelled FNB needles achieved a high diagnostic sensitivity. The 20G‐side‐bevelledAbstract : Background: Innovative approaches to improve diagnostic yield of endoscopic ultrasound‐guided tissue acquisition (EUS‐TA) have focused on needle design with development of fine‐needle biopsy (FNB) needles with microcore‐acquisition technology. Recently, a 20‐gauge (20G) antegrade‐cutting‐side‐bevelled biopsy needle (ProCore®) was developed for EUS‐TA, but data about its diagnostic performance and histological capability are scant. Objectives: We assessed the diagnostic performance and histologic retrieval rate of a new 20G antegrade‐cutting‐side‐bevelled biopsy needle compared with a 22G reverse‐side‐bevelled needle for EUS sampling of solid pancreatic lesions. Patients and methods: A retrospective analysis of 238 consecutively collected patients who underwent EUS‐TA using a 20G or a 22G ProCore® needle, without rapid on‐site evaluation (ROSE), was conducted at two centres. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Histologic tissue retrieval was evaluated applying a scoring system for each case. Results: Sensitivity and specificity were estimated as 98.4–100% in the 20G‐, and 94.9–100% in the 22G‐needle groups, respectively ( p > 0.99). The 20G procured more histologic‐grade tissues (92.6% vs 49.5%, p < 0.0001) achieved by a lower number of passes (2.64 vs 3.44, p < 0.0001) compared to the 22G. Conclusions: Both side‐bevelled FNB needles achieved a high diagnostic sensitivity. The 20G‐side‐bevelled needle obtained a significantly higher microcore retrieval rate. … (more)
- Is Part Of:
- United European Gastroenterology journal. Volume 7:Issue 1(2019)
- Journal:
- United European Gastroenterology journal
- Issue:
- Volume 7:Issue 1(2019)
- Issue Display:
- Volume 7, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2019-0007-0001-0000
- Page Start:
- 96
- Page End:
- 104
- Publication Date:
- 2019-02-01
- Subjects:
- Endosonography -- endoscopic ultrasound-guided tissue acquisition -- fine-needle biopsy (FNB) -- pancreatic cancer -- 20G ProCore® -- solid pancreatic neoplasm
Gastroenterology -- Periodicals
Periodicals
616.33005 - Journal URLs:
- https://onlinelibrary.wiley.com/loi/20506414 ↗
http://www.uk.sagepub.com ↗
http://ueg.sagepub.com/ ↗ - DOI:
- 10.1177/2050640618804443 ↗
- Languages:
- English
- ISSNs:
- 2050-6406
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16499.xml