Effect of interface mechanical discontinuities on scaffold‐cartilage integration. Issue 4 (20th March 2019)
- Record Type:
- Journal Article
- Title:
- Effect of interface mechanical discontinuities on scaffold‐cartilage integration. Issue 4 (20th March 2019)
- Main Title:
- Effect of interface mechanical discontinuities on scaffold‐cartilage integration
- Authors:
- Yodmuang, Supansa
Guo, Hongqiang
Brial, Caroline
Warren, Russell F.
Torzilli, Peter A.
Chen, Tony
Maher, Suzanne A. - Abstract:
- ABSTRACT: A consistent lack of lateral integration between scaffolds and adjacent articular cartilage has been exhibited in vitro and in vivo. Given the mismatch in mechanical properties between scaffolds and articular cartilage, the mechanical discontinuity that occurs at the interface has been implicated as a key factor, but remains inadequately studied. Our objective was to investigate how the mechanical environment within a mechanically loaded scaffold‐cartilage construct might affect integration. We hypothesized that the magnitude of the mechanical discontinuity at the scaffold‐cartilage interface would be related to decreased integration. To test this hypothesis, chondrocyte seeded scaffolds were embedded into cartilage explants, pre‐cultured for 14 days, and then mechanically loaded for 28 days at either 1N or 6N of applied load. Constructs were kept either peripherally confined or unconfined throughout the duration of the experiment. Stress, strain, fluid flow, and relative displacements at the cartilage‐scaffold interface and within the scaffold were quantified using biphasic, inhomogeneous finite element models (bFEMs). The bFEMs indicated compressive and shear stress discontinuities occurred at the scaffold‐cartilage interface for the confined and unconfined groups. The mechanical strength of the scaffold‐cartilage interface and scaffold GAG content were higher in the radially confined 1N loaded groups. Multivariate regression analyses identified the strength ofABSTRACT: A consistent lack of lateral integration between scaffolds and adjacent articular cartilage has been exhibited in vitro and in vivo. Given the mismatch in mechanical properties between scaffolds and articular cartilage, the mechanical discontinuity that occurs at the interface has been implicated as a key factor, but remains inadequately studied. Our objective was to investigate how the mechanical environment within a mechanically loaded scaffold‐cartilage construct might affect integration. We hypothesized that the magnitude of the mechanical discontinuity at the scaffold‐cartilage interface would be related to decreased integration. To test this hypothesis, chondrocyte seeded scaffolds were embedded into cartilage explants, pre‐cultured for 14 days, and then mechanically loaded for 28 days at either 1N or 6N of applied load. Constructs were kept either peripherally confined or unconfined throughout the duration of the experiment. Stress, strain, fluid flow, and relative displacements at the cartilage‐scaffold interface and within the scaffold were quantified using biphasic, inhomogeneous finite element models (bFEMs). The bFEMs indicated compressive and shear stress discontinuities occurred at the scaffold‐cartilage interface for the confined and unconfined groups. The mechanical strength of the scaffold‐cartilage interface and scaffold GAG content were higher in the radially confined 1N loaded groups. Multivariate regression analyses identified the strength of the interface prior to the commencement of loading and fluid flow within the scaffold as the main factors associated with scaffold‐cartilage integration. Our study suggests a minimum level of scaffold‐cartilage integration is needed prior to the commencement of loading, although the exact threshold has yet to be identified. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 37:Issue 4(2019)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 37:Issue 4(2019)
- Issue Display:
- Volume 37, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 37
- Issue:
- 4
- Issue Sort Value:
- 2019-0037-0004-0000
- Page Start:
- 845
- Page End:
- 854
- Publication Date:
- 2019-03-20
- Subjects:
- biomechanics scaffold‐cartilage interface -- articular cartilage and mechanical loading
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.24238 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16459.xml