Automatic method for vertebral morphometry measurements. Issue 4 (1st July 2016)
- Record Type:
- Journal Article
- Title:
- Automatic method for vertebral morphometry measurements. Issue 4 (1st July 2016)
- Main Title:
- Automatic method for vertebral morphometry measurements
- Authors:
- Franchini, Roberto
Conversano, Francesco
Pisani, Paola
Casciaro, Ernesto
Peccarisi, Marco
Quarta, Eugenio
Grimaldi, Antonella
Muratore, Maurizio
Casciaro, Sergio - Abstract:
- Abstract : Aim of this study was to perform a detailed clinical validation of a novel fully automatic method for vertebral morphometry. About 80 spine lateral radiographs were evaluated both automatically, by the proposed algorithm, and manually, by an experienced radiologist. The following metrics were used for algorithm performance assessment: sensitivity and specificity in vertebra detection; errors in the localisation of characteristic points of vertebral border; errors in the measurement of six diagnostic parameters; level of agreement and correlation between manual and automatic morphometric measurements; overall accuracy of automatic diagnoses with respect to manual ones. Obtained results showed a very good performance in vertebra detection (sensitivity = 89.1% and specificity = 100.0%). Average errors in the localisation of vertebral characteristic points were always smaller than 3 mm (range 0.85–2.79 mm), causing relative errors in diagnostic parameter values ranging from −5.01 to +6.10%. Bland–Altman analysis documented a mean error in automatic measurements of diagnostic ratios of 0.01 ± 0.18 (bias ± 2 SDs), while Pearson's correlation coefficient resulted r = 0.71 ( p < 0.001). Finally, an optimal diagnostic coincidence (92.8%) was found between automatic and manual diagnoses. Therefore, the adopted method has a potential for an effective employment in clinical routine for reliable diagnosis of vertebral fractures.
- Is Part Of:
- IET science, measurement & technology. Volume 10:Issue 4(2016)
- Journal:
- IET science, measurement & technology
- Issue:
- Volume 10:Issue 4(2016)
- Issue Display:
- Volume 10, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 4
- Issue Sort Value:
- 2016-0010-0004-0000
- Page Start:
- 327
- Page End:
- 334
- Publication Date:
- 2016-07-01
- Subjects:
- fracture -- bone -- diagnostic radiography -- biomechanics
vertebral morphometry measurements -- spine lateral radiographs -- vertebra detection -- Bland–Altman analysis -- Pearson correlation coefficient -- optimal diagnostic coincidence -- manual morphometric measurement -- automatic morphometric measurement -- vertebral fractures
Measurement -- Periodicals
Electrical engineering -- Periodicals
Electronics -- Periodicals
Nanotechnology -- Periodicals
Electromagnetism -- Periodicals
Medical instruments and apparatus -- Periodicals
621.3 - Journal URLs:
- https://ietresearch.onlinelibrary.wiley.com/loi/17518830 ↗
http://digital-library.theiet.org/content/journals/iet-smt ↗
http://ieeexplore.ieee.org/servlet/opac?punumber=4105888 ↗
http://www.theiet.org/ ↗
http://www.ietdl.org/IP-SMT ↗ - DOI:
- 10.1049/iet-smt.2015.0172 ↗
- Languages:
- English
- ISSNs:
- 1751-8822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4363.253530
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16431.xml