Measurement of quartz crystal unit parameters based on the precise derivation of zero phase frequency. Issue 3 (1st February 2017)
- Record Type:
- Journal Article
- Title:
- Measurement of quartz crystal unit parameters based on the precise derivation of zero phase frequency. Issue 3 (1st February 2017)
- Main Title:
- Measurement of quartz crystal unit parameters based on the precise derivation of zero phase frequency
- Authors:
- Liu, Dong
Huang, Xianhe
Hu, Jianguo
Tang, Yuanlin
Wang, Yan - Abstract:
- Abstract : It is usually considered that the resonance frequency of quartz crystal resonator is only related to dynamic inductance L 1 and dynamic capacitance C 1, and load resonance frequency has connection with L 1, C 1 and static capacitance C 0 . Hence, the dynamic resistance cannot be measured by frequency. The deduction show that all the frequencies relates to L 1, C 1, C 0 and dynamic resistance R 1 . Then, a method for measuring the total equivalent parameters of quartz crystal resonator based on zero phase frequency is proposed in this Letter. The simulation results of advanced design system (ADS) verify the validity of this proposal in theory. After that, the phase‐frequency‐curves of a quartz crystal resonator with 10 and 5 MHz are measured, which can obtain equivalent parameters of through data processing. The results show that this method has calculated parameters essentially in agreement with nominal parameters. This method does not have reciprocating debugging process, and the test process is simple as well. In addition, the approximate calculation is not used in this method, and it could be widely extent to the field of sensors, such as quartz crystal microbalance sensors, temperature sensors and so on.
- Is Part Of:
- Electronics letters. Volume 53:Issue 3(2017)
- Journal:
- Electronics letters
- Issue:
- Volume 53:Issue 3(2017)
- Issue Display:
- Volume 53, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 53
- Issue:
- 3
- Issue Sort Value:
- 2017-0053-0003-0000
- Page Start:
- 142
- Page End:
- 144
- Publication Date:
- 2017-02-01
- Subjects:
- crystal resonators -- frequency measurement -- phase measurement -- approximation theory
quartz crystal unit parameter measurement -- zero phase frequency -- quartz crystal resonator -- advanced design system -- ADS -- phase frequency‐curve -- data processing -- debugging process -- approximate calculation -- quartz crystal microbalance sensor -- temperature sensor -- frequency 10 MHz -- frequency 5 MHz
Electronics -- Periodicals
621.381 - Journal URLs:
- http://digital-library.theiet.org/content/journals/el ↗
http://estar.bl.uk/cgi-bin/sciserv.pl?collection=journals&journal=00135194 ↗
https://ietresearch.onlinelibrary.wiley.com/loi/1350911x ↗
http://www.theiet.org/ ↗ - DOI:
- 10.1049/el.2016.4320 ↗
- Languages:
- English
- ISSNs:
- 0013-5194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3705.060000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16440.xml