Calibration of triaxial MEMS vector field measurement system. Issue 6 (1st November 2014)
- Record Type:
- Journal Article
- Title:
- Calibration of triaxial MEMS vector field measurement system. Issue 6 (1st November 2014)
- Main Title:
- Calibration of triaxial MEMS vector field measurement system
- Authors:
- Xiaoming, Zhang
Guobin, Chen
Jie, Li
Jun, Liu - Abstract:
- Abstract : Triaxial MEMS vector field measurement system with triaxial MEMS sensors, such as accelerometer and magnetometer, is typically used to acquire navigation information in strap‐down inertial navigation system (SINS). The navigation accuracy of the body is directly affected by the measurement accuracy of the measurement system. This study presents a two‐step calibration algorithm for the triaxial MEMS vector field measurement system based on a detailed analysis of the measurement system error model. In the calibration procedure of this method, the first step is to calibrate the triaxial vector sensor error, including bias, scale factors and non‐orthogonality using the ellipsoid fitting method; the second step is to calibrate the misalignment between the orthogonal sensor frame and the system body frame using the four‐position method. Furthermore, the mathematical analysis of four‐position method calibration error is done to study on the factors influencing the misalignment calibration accuracy, numerical simulation and experiments, which are performed for validating the analysis. A series of calibration experiments on a triaxial MEMS accelerometer in the measurement system show significant enhancement of the accuracy of three components measurement data in the system body frame.
- Is Part Of:
- IET science, measurement & technology. Volume 8:Issue 6(2014)
- Journal:
- IET science, measurement & technology
- Issue:
- Volume 8:Issue 6(2014)
- Issue Display:
- Volume 8, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 8
- Issue:
- 6
- Issue Sort Value:
- 2014-0008-0006-0000
- Page Start:
- 601
- Page End:
- 609
- Publication Date:
- 2014-11-01
- Subjects:
- calibration -- microsensors -- accelerometers -- magnetometers -- inertial navigation -- measurement errors -- mathematical analysis
triaxial MEMS vector field measurement system -- triaxial MEMS vector sensor -- accelerometer -- magnetometer -- strapdown inertial navigation system -- SINS -- two‐step calibration algorithm -- measurement system error model -- ellipsoid fitting method -- orthogonal sensor frame -- system body frame -- four‐position method -- mathematical analysis -- numerical simulation
Measurement -- Periodicals
Electrical engineering -- Periodicals
Electronics -- Periodicals
Nanotechnology -- Periodicals
Electromagnetism -- Periodicals
Medical instruments and apparatus -- Periodicals
621.3 - Journal URLs:
- https://ietresearch.onlinelibrary.wiley.com/loi/17518830 ↗
http://digital-library.theiet.org/content/journals/iet-smt ↗
http://ieeexplore.ieee.org/servlet/opac?punumber=4105888 ↗
http://www.theiet.org/ ↗
http://www.ietdl.org/IP-SMT ↗ - DOI:
- 10.1049/iet-smt.2013.0202 ↗
- Languages:
- English
- ISSNs:
- 1751-8822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4363.253530
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16424.xml