Simplification and cost reduction of visual corona tests. Issue 4 (12th January 2018)
- Record Type:
- Journal Article
- Title:
- Simplification and cost reduction of visual corona tests. Issue 4 (12th January 2018)
- Main Title:
- Simplification and cost reduction of visual corona tests
- Authors:
- Riba, Jordi‐Roger
Abomailek, Carlos
Casals‐Torrens, Pau
Capelli, Francesca - Abstract:
- Abstract : Visual corona tests are useful to identify the critical corona points of different high‐voltage components. Radio interference voltage and partial discharge measurements also allow detecting corona activity. However, these techniques require expensive screened laboratories, sophisticated instrumentation and usually do not provide the exact location of the discharges. Corona tests are often performed in external laboratories, where customers habitually have to face long waiting times. The tests in such laboratories must be totally planned beforehand, as they are habitually done by external engineers, so little information about the behaviour and possible modifications of the product is acquired by the customer. This study proposes a feasible solution to perform routine corona tests, while greatly reducing the voltage applied, laboratory size and requirements, testing times, and thus test costs. This study also detects the visual corona onset by means of a commercial digital camera, which allows locating the critical corona points, thus greatly decreasing the costs of the corona instrumentation, while maintaining the accuracy and sensitivity of the detection method. The methodology proposed in this study can be applied to many other high‐voltage devices such as conductors, vibration dumpers, corona protections and different types of hardware and fittings for power lines and substations.
- Is Part Of:
- IET generation, transmission & distribution. Volume 12:Issue 4(2018)
- Journal:
- IET generation, transmission & distribution
- Issue:
- Volume 12:Issue 4(2018)
- Issue Display:
- Volume 12, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 12
- Issue:
- 4
- Issue Sort Value:
- 2018-0012-0004-0000
- Page Start:
- 834
- Page End:
- 841
- Publication Date:
- 2018-01-12
- Subjects:
- corona -- cost reduction -- substations -- electric connectors -- partial discharge measurement -- radiofrequency interference -- production facilities -- test facilities
cost reduction -- visual corona tests -- critical corona point identification -- substation connectors -- high‐voltage components -- radio interference voltage -- partial discharge measurements -- corona activity detection -- product optimisation -- industrial facilities -- visual corona onset detection -- commercial digital camera -- corona detection instrumentation -- high‐voltage devices
Electric power production -- Periodicals
Electric power transmission -- Periodicals
Electric power distribution -- Periodicals
621.3105 - Journal URLs:
- http://digital-library.theiet.org/content/journals/iet-gtd ↗
http://ieeexplore.ieee.org/servlet/opac?punumber=4082359 ↗
http://www.ietdl.org/IET-GTD ↗
https://ietresearch.onlinelibrary.wiley.com/journal/17518695 ↗
http://www.theiet.org/ ↗ - DOI:
- 10.1049/iet-gtd.2017.0688 ↗
- Languages:
- English
- ISSNs:
- 1751-8687
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4363.252540
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16419.xml