Rapid LC–MS/MS quantification of the major benzodiazepines and their metabolites on dried blood spots using a simple and cost-effective sample pretreatment. (June 2012)
- Record Type:
- Journal Article
- Title:
- Rapid LC–MS/MS quantification of the major benzodiazepines and their metabolites on dried blood spots using a simple and cost-effective sample pretreatment. (June 2012)
- Main Title:
- Rapid LC–MS/MS quantification of the major benzodiazepines and their metabolites on dried blood spots using a simple and cost-effective sample pretreatment
- Authors:
- Déglon, Julien
Versace, François
Lauer, Estelle
Widmer, Christèle
Mangin, Patrice
Thomas, Aurélien
Staub, Christian - Abstract:
- Background: Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC–MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial.Results: The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds.Conclusion: The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
- Is Part Of:
- Bioanalysis. Volume 4:Number 11(2012)
- Journal:
- Bioanalysis
- Issue:
- Volume 4:Number 11(2012)
- Issue Display:
- Volume 4, Issue 11 (2012)
- Year:
- 2012
- Volume:
- 4
- Issue:
- 11
- Issue Sort Value:
- 2012-0004-0011-0000
- Page Start:
- 1337
- Page End:
- 1350
- Publication Date:
- 2012-06
- Subjects:
- Drugs -- Analysis -- Periodicals
615.19005 - Journal URLs:
- http://www.future-science.com/loi/bio ↗
http://www.future-science.com/ ↗ - DOI:
- 10.4155/bio.12.42 ↗
- Languages:
- English
- ISSNs:
- 1757-6180
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16383.xml