Validation of a secondary dose check tool against Monte Carlo and analytical clinical dose calculation algorithms in VMAT. Issue 4 (18th March 2021)
- Record Type:
- Journal Article
- Title:
- Validation of a secondary dose check tool against Monte Carlo and analytical clinical dose calculation algorithms in VMAT. Issue 4 (18th March 2021)
- Main Title:
- Validation of a secondary dose check tool against Monte Carlo and analytical clinical dose calculation algorithms in VMAT
- Authors:
- Piffer, Stefano
Casati, Marta
Marrazzo, Livia
Arilli, Chiara
Calusi, Silvia
Desideri, Isacco
Fusi, Franco
Pallotta, Stefania
Talamonti, Cinzia - Abstract:
- Abstract: Purpose: Patient‐specific quality assurance (QA) is very important in radiotherapy, especially for patients with highly conformed treatment plans like VMAT plans. Traditional QA protocols for these plans are time‐consuming reducing considerably the time available for patient treatments. In this work, a new MC‐based secondary dose check software (SciMoCa) is evaluated and benchmarked against well‐established TPS (Monaco and Pinnacle 3 ) by means of treatment plans and dose measurements. Methods: Fifty VMAT plans have been computed using same calculation parameters with SciMoCa and the two primary TPSs. Plans were validated with measurements performed with a 3D diode detector (ArcCHECK) by translating patient plans to phantom geometry. Calculation accuracy was assessed by measuring point dose differences and gamma passing rates (GPR) from a 3D gamma analysis with 3%–2 mm criteria. Comparison between SciMoCa and primary TPS calculations was made using the same estimators and using both patient and phantom geometry plans. Results: TPS and SciMoCa calculations were found to be in very good agreement with validation measurements with average point dose differences of 0.7 ± 1.7% and −0.2 ± 1.6% for SciMoCa and two TPSs, respectively. Comparison between SciMoCa calculations and the two primary TPS plans did not show any statistically significant difference with average point dose differences compatible with zero within error for both patient and phantom geometry plans andAbstract: Purpose: Patient‐specific quality assurance (QA) is very important in radiotherapy, especially for patients with highly conformed treatment plans like VMAT plans. Traditional QA protocols for these plans are time‐consuming reducing considerably the time available for patient treatments. In this work, a new MC‐based secondary dose check software (SciMoCa) is evaluated and benchmarked against well‐established TPS (Monaco and Pinnacle 3 ) by means of treatment plans and dose measurements. Methods: Fifty VMAT plans have been computed using same calculation parameters with SciMoCa and the two primary TPSs. Plans were validated with measurements performed with a 3D diode detector (ArcCHECK) by translating patient plans to phantom geometry. Calculation accuracy was assessed by measuring point dose differences and gamma passing rates (GPR) from a 3D gamma analysis with 3%–2 mm criteria. Comparison between SciMoCa and primary TPS calculations was made using the same estimators and using both patient and phantom geometry plans. Results: TPS and SciMoCa calculations were found to be in very good agreement with validation measurements with average point dose differences of 0.7 ± 1.7% and −0.2 ± 1.6% for SciMoCa and two TPSs, respectively. Comparison between SciMoCa calculations and the two primary TPS plans did not show any statistically significant difference with average point dose differences compatible with zero within error for both patient and phantom geometry plans and GPR (98.0 ± 3.0% and 99.0 ± 3.0% respectively) well in excess of the typical 95 % clinical tolerance threshold. Conclusion: This work presents results obtained with a significantly larger sample than other similar analyses and, to the authors' knowledge, compares SciMoCa with a MC‐based TPS for the first time. Results show that a MC‐based secondary patient‐specific QA is a clinically viable, reliable, and promising technique, that potentially allows significant time saving that can be used for patient treatment and a per‐plan basis QA that effectively complements traditional commissioning and calibration protocols. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 4(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 4(2021)
- Issue Display:
- Volume 22, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 4
- Issue Sort Value:
- 2021-0022-0004-0000
- Page Start:
- 52
- Page End:
- 62
- Publication Date:
- 2021-03-18
- Subjects:
- independent secondary dose check -- Monte Carlo -- Patient Specific Quality Assurance -- Pre‐treatment verification
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13209 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16356.xml