Automated Noninvasive Central Blood Pressure Measurements by Oscillometric Radial Pulse Wave Analysis: Results of the MEASURE-cBP Validation Studies. (3rd November 2020)
- Record Type:
- Journal Article
- Title:
- Automated Noninvasive Central Blood Pressure Measurements by Oscillometric Radial Pulse Wave Analysis: Results of the MEASURE-cBP Validation Studies. (3rd November 2020)
- Main Title:
- Automated Noninvasive Central Blood Pressure Measurements by Oscillometric Radial Pulse Wave Analysis: Results of the MEASURE-cBP Validation Studies
- Authors:
- Trinkmann, Frederik
Benck, Urs
Halder, Julian
Semmelweis, Alexandra
Saur, Joachim
Borggrefe, Martin
Akin, Ibrahim
Kaden, Jens J - Abstract:
- Abstract: Background: Central blood pressure becomes increasingly accepted as an important diagnostic and therapeutic parameter. Accuracy of widespread applanation tonometry can be affected by calibration and operator training. To overcome this, we aimed to evaluate novel VascAssist 2 using automated oscillometric radial pulse wave analysis and a refined multi-compartment model of the arterial tree. Methods: Two hundred and twenty-five patients were prospectively enrolled. Invasive aortic root measurements served as reference in MEASURE-cBP 1 ( n = 106) whereas applanation tonometry (SphygmoCor) was used in MEASURE-cBP 2 ( n = 119). Results: In MEASURE-cBP 1, we found a mean overestimation for systolic values of 4 ± 12 mmHg (3 ± 10%) and 6 ± 10 mmHg (9 ± 14%) for diastolic values. Diabetes mellitus and low blood pressure were associated with larger variation. In MEASURE-cBP 2, mean overestimation of systolic values was 4 ± 4 mmHg (4 ± 4%) and 1 ± 4 mmHg (1 ± 7%) of diastolic values. Arrhythmia was significantly more frequent in invalid measurements (61 vs. 18%, P < 0.0001) which were most often due to a low quality index of SphygmoCor. Conclusions: Central blood pressure estimates using VascAssist 2 can be considered at least as accurate as available techniques, even including diabetic patients. In direct comparison, automated measurement considerably facilitates application not requiring operator training and can be reliably applied even in patients with arrhythmias.
- Is Part Of:
- American journal of hypertension. Volume 34:Number 4(2021)
- Journal:
- American journal of hypertension
- Issue:
- Volume 34:Number 4(2021)
- Issue Display:
- Volume 34, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2021-0034-0004-0000
- Page Start:
- 383
- Page End:
- 393
- Publication Date:
- 2020-11-03
- Subjects:
- blood pressure -- central blood pressure -- hypertension -- MEASURE-cBP -- noninvasive -- oscillometric pulse wave analysis -- SphygmoCor -- validation -- VascAssist 2
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://ajh.oxfordjournals.org/ ↗
http://www.nature.com/ajh/index.html ↗
http://ukcatalogue.oup.com/ ↗
http://www.sciencedirect.com/science/journal/08957061 ↗ - DOI:
- 10.1093/ajh/hpaa174 ↗
- Languages:
- English
- ISSNs:
- 0895-7061
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0826.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16337.xml