Impact of the combined use of intracardiac ultrasound and a steerable sheath visualized by a 3D mapping system on pulmonary vein isolation. Issue 4 (11th March 2021)
- Record Type:
- Journal Article
- Title:
- Impact of the combined use of intracardiac ultrasound and a steerable sheath visualized by a 3D mapping system on pulmonary vein isolation. Issue 4 (11th March 2021)
- Main Title:
- Impact of the combined use of intracardiac ultrasound and a steerable sheath visualized by a 3D mapping system on pulmonary vein isolation
- Authors:
- Wakamatsu, Yuji
Nagashima, Koichi
Kurokawa, Sayaka
Otsuka, Naoto
Hayashida, Satoshi
Yagyu, Seina
Hirata, Shu
Ohkubo, Kimie
Nakai, Toshiko
Okumura, Yasuo - Abstract:
- Abstract: Background: A novel steerable sheath visualized on a three‐dimensional mapping system has become available in this era in which a durable pulmonary vein (PV) isolation (PVI) with reduced fluoroscopy is required. Methods: In 60 patients who underwent a PVI with a visualized sheath ( n = 30) and non‐visualized conventional sheath ( n = 30), the fluoroscopic time and catheter stability during the PVI were analyzed. Results: The fluoroscopic time during the transseptal access (0 [0, 0.1] vs. 1.4 [0.8, 2.3] minutes, P < .001) and PVI (0 [0, 0.1] vs. 0.4 [0.2, 1.1] minutes, P < .001) were shorter in the visualized sheath group than conventional sheath group. The procedure time during the PVI (32.0 [26.8, 36.3] vs. 41.0 [31.8, 47.3] minutes, P = .01), particularly during the right PVI (15.0 [12.8, 18.0] vs. 23.0 [15.8, 26.3] minutes, P = .009), was shorter in the visualized sheath group than conventional sheath group, however, that during the other steps was equivalent. The standard deviation of the catheter contact force during each radiofrequency application was smaller in the visualized sheath group than conventional sheath group (4.5 ± 2.7 vs. 4.9 ± 3.1 g, P = .001). The impedance drop for each lesion was larger in the visualized sheath group than conventional sheath group (10.7 ± 6.5 vs. 9.8 ± 5.5 ohms, P < .001). The incidence of acute PV reconnections per patient (30% vs. 23%, P = .56) and per PV segment (2.5% vs. 2.3%, P = .83) were similar between theAbstract: Background: A novel steerable sheath visualized on a three‐dimensional mapping system has become available in this era in which a durable pulmonary vein (PV) isolation (PVI) with reduced fluoroscopy is required. Methods: In 60 patients who underwent a PVI with a visualized sheath ( n = 30) and non‐visualized conventional sheath ( n = 30), the fluoroscopic time and catheter stability during the PVI were analyzed. Results: The fluoroscopic time during the transseptal access (0 [0, 0.1] vs. 1.4 [0.8, 2.3] minutes, P < .001) and PVI (0 [0, 0.1] vs. 0.4 [0.2, 1.1] minutes, P < .001) were shorter in the visualized sheath group than conventional sheath group. The procedure time during the PVI (32.0 [26.8, 36.3] vs. 41.0 [31.8, 47.3] minutes, P = .01), particularly during the right PVI (15.0 [12.8, 18.0] vs. 23.0 [15.8, 26.3] minutes, P = .009), was shorter in the visualized sheath group than conventional sheath group, however, that during the other steps was equivalent. The standard deviation of the catheter contact force during each radiofrequency application was smaller in the visualized sheath group than conventional sheath group (4.5 ± 2.7 vs. 4.9 ± 3.1 g, P = .001). The impedance drop for each lesion was larger in the visualized sheath group than conventional sheath group (10.7 ± 6.5 vs. 9.8 ± 5.5 ohms, P < .001). The incidence of acute PV reconnections per patient (30% vs. 23%, P = .56) and per PV segment (2.5% vs. 2.3%, P = .83) were similar between the two groups. No major complications occurred in either sheath group. Conclusions: The use of visualized sheaths may reduce the fluoroscopic time and improve the catheter stability during the PVI. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 44:Issue 4(2021)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 44:Issue 4(2021)
- Issue Display:
- Volume 44, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 4
- Issue Sort Value:
- 2021-0044-0004-0000
- Page Start:
- 693
- Page End:
- 702
- Publication Date:
- 2021-03-11
- Subjects:
- atrial fibrillation -- catheter ablation -- catheter stability -- fluoroscopic time -- pulmonary vein isolation
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.14194 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16318.xml