Impact of contact force sensing technology on outcome of catheter ablation of idiopathic pre-mature ventricular contractions originating from the outflow tracts. Issue 4 (18th November 2020)
- Record Type:
- Journal Article
- Title:
- Impact of contact force sensing technology on outcome of catheter ablation of idiopathic pre-mature ventricular contractions originating from the outflow tracts. Issue 4 (18th November 2020)
- Main Title:
- Impact of contact force sensing technology on outcome of catheter ablation of idiopathic pre-mature ventricular contractions originating from the outflow tracts
- Authors:
- Reichlin, Tobias
Baldinger, Samuel H
Pruvot, Etienne
Bisch, Laurence
Ammann, Peter
Altmann, David
Berte, Benjamin
Kobza, Richard
Haegeli, Laurent
Schlatzer, Christian
Mueller, Andreas
Namdar, Mehdi
Shah, Dipen
Burri, Haran
Conte, Giulio
Auricchio, Angelo
Knecht, Sven
Osswald, Stefan
Asatryan, Babken
Seiler, Jens
Roten, Laurent
Kühne, Michael
Sticherling, Christian - Abstract:
- Abstract: Aims: Catheter ablation of frequent idiopathic pre-mature ventricular contractions (PVC) is increasingly performed. While potential benefits of contact force (CF)-sensing technology for atrial fibrillation ablation have been assessed in several studies, the impact of CF-sensing on ventricular arrhythmia ablation remains unknown. This study aimed to compare outcomes of idiopathic outflow tract PVC ablation when using standard ablation catheters as opposed to CF-sensing catheters. Methods and results: In a retrospective multi-centre study, unselected patients undergoing catheter ablation of idiopathic outflow tract PVCs between 2013 and 2016 were enrolled. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24 h Holter ECG during follow-up. Overall, 218 patients were enrolled (median age 52 years, 51% males). Baseline and procedural data were similar in the standard ablation (24%) and the CF-sensing group (76%). Overall, the median PVC burden decreased from 21% (IQR 10–30%) before ablation to 0.2% (IQR 0–3.0%) after a median follow-up of 2.3 months (IQR 1.4–3.9 months). The rates of both acute (91% vs. 91%, P = 0.94) and sustained success (79% vs. 74%, P = 0.44) were similar in the standard ablation and the CF-sensing groups. No differences were observed in subgroups according to arrhythmia origin fromAbstract: Aims: Catheter ablation of frequent idiopathic pre-mature ventricular contractions (PVC) is increasingly performed. While potential benefits of contact force (CF)-sensing technology for atrial fibrillation ablation have been assessed in several studies, the impact of CF-sensing on ventricular arrhythmia ablation remains unknown. This study aimed to compare outcomes of idiopathic outflow tract PVC ablation when using standard ablation catheters as opposed to CF-sensing catheters. Methods and results: In a retrospective multi-centre study, unselected patients undergoing catheter ablation of idiopathic outflow tract PVCs between 2013 and 2016 were enrolled. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24 h Holter ECG during follow-up. Overall, 218 patients were enrolled (median age 52 years, 51% males). Baseline and procedural data were similar in the standard ablation (24%) and the CF-sensing group (76%). Overall, the median PVC burden decreased from 21% (IQR 10–30%) before ablation to 0.2% (IQR 0–3.0%) after a median follow-up of 2.3 months (IQR 1.4–3.9 months). The rates of both acute (91% vs. 91%, P = 0.94) and sustained success (79% vs. 74%, P = 0.44) were similar in the standard ablation and the CF-sensing groups. No differences were observed in subgroups according to arrhythmia origin from the RVOT (65%) or LVOT (35%). Complications were rare (1.8%) and evenly distributed between the two groups. Conclusion: The use of CF-sensing technology is not associated with increased success rate nor decreased complication rate in idiopathic outflow tract PVC ablation. … (more)
- Is Part Of:
- Europace. Volume 23:Issue 4(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Issue 4(2021)
- Issue Display:
- Volume 23, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 4
- Issue Sort Value:
- 2021-0023-0004-0000
- Page Start:
- 603
- Page End:
- 609
- Publication Date:
- 2020-11-18
- Subjects:
- Premature ventricular contraction -- Catheter ablation -- Contact-force catheter -- Idiopathic ventricular arrhythmia -- Outcome
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa315 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16318.xml