Inhaled salbutamol from aerolizer and diskus at different inhalation flows, inhalation volume and number of inhalations in both healthy subjects and COPD patients. (21st April 2019)
- Record Type:
- Journal Article
- Title:
- Inhaled salbutamol from aerolizer and diskus at different inhalation flows, inhalation volume and number of inhalations in both healthy subjects and COPD patients. (21st April 2019)
- Main Title:
- Inhaled salbutamol from aerolizer and diskus at different inhalation flows, inhalation volume and number of inhalations in both healthy subjects and COPD patients
- Authors:
- Boshra, Marian S.
Almeldien, Ahmed G.
Eldin, Randa Salah
Elberry, Ahmed A.
Abdelwahab, Nada Sayed
Salem, Mohamed Nabil
Rabea, Hoda
Abdelrahim, Mohamed E. A. - Abstract:
- Abstract: The aim of the present study was to demonstrate the effect of inhalation-flow, inhalation-volume and number of inhalations on aerosol-delivery of inhaled-salbutamol from two different dry powder inhalers (DPIs) in both healthy-subjects and chronic obstructive pulmonary disease (COPD) patients. Relative pulmonary-bioavailability and systemic-bioavailability of inhaled-salbutamol, delivered by Diskus and Aerolizer, was determined in 24-COPD patients and 24-healthy subjects. The healthy-subjects and the COPD-patients participated in the study for 7 days in which they received 4 study doses of 200 μg salbutamol (one slow-inhalation, two slow-inhalations, one fast-inhalation, and two fast-inhalations) in four alternative days with 24 hr washout period after each dose. Two urine-samples were collected from each study subjects. The first was provided 30 min post inhalation (USAL0.5), as an index of relative pulmonary-bioavailability, and the second was pooled to 24 hr post inhalation (USAL24), as an index of systemic-bioavailability. Fast-inhalation resulted in significantly higher USAL0.5 and USAL24 than slow-inhalation (p < 0.05) after one-inhalation in both healthy-subjects and COPD-patients but there was no significant difference between slow and fast-inhalation after two-inhalations. One-inhalation resulted in significantly higher USAL0.5 and USAL24 in healthy-subjects compared to COPD-patient at both slow and fast-inhalation (p < 0.05) except USAL0.5 with Diskus atAbstract: The aim of the present study was to demonstrate the effect of inhalation-flow, inhalation-volume and number of inhalations on aerosol-delivery of inhaled-salbutamol from two different dry powder inhalers (DPIs) in both healthy-subjects and chronic obstructive pulmonary disease (COPD) patients. Relative pulmonary-bioavailability and systemic-bioavailability of inhaled-salbutamol, delivered by Diskus and Aerolizer, was determined in 24-COPD patients and 24-healthy subjects. The healthy-subjects and the COPD-patients participated in the study for 7 days in which they received 4 study doses of 200 μg salbutamol (one slow-inhalation, two slow-inhalations, one fast-inhalation, and two fast-inhalations) in four alternative days with 24 hr washout period after each dose. Two urine-samples were collected from each study subjects. The first was provided 30 min post inhalation (USAL0.5), as an index of relative pulmonary-bioavailability, and the second was pooled to 24 hr post inhalation (USAL24), as an index of systemic-bioavailability. Fast-inhalation resulted in significantly higher USAL0.5 and USAL24 than slow-inhalation (p < 0.05) after one-inhalation in both healthy-subjects and COPD-patients but there was no significant difference between slow and fast-inhalation after two-inhalations. One-inhalation resulted in significantly higher USAL0.5 and USAL24 in healthy-subjects compared to COPD-patient at both slow and fast-inhalation (p < 0.05) except USAL0.5 with Diskus at slow-inhalation there was no significant difference. Also, two-inhalations resulted in significantly higher USAL0.5 and USAL24 compared to one-inhalation at slow-inhalation only (p < 0.05). No significant difference was found between Aerolizer and Diskus except in USAL0.5 of one slow-inhalation in both health-subjects and COPD-patients (p = 0.048 and 0.047, respectively). Device-formula relation is present at low inhalation-flow since Diskus resulted in significantly higher USAL0.5 and USAL24 in healthy-subjects compared to COPD-patient at slow inhalation than Aerolizer. It is essential to inhale-twice and as hard and deep as possible from each dose when using DPI especially with COPD-patients having poor inspiratory efforts such as elderly patients and children. … (more)
- Is Part Of:
- Experimental lung research. Volume 45:Number 3/4(2019)
- Journal:
- Experimental lung research
- Issue:
- Volume 45:Number 3/4(2019)
- Issue Display:
- Volume 45, Issue 3/4 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 3/4
- Issue Sort Value:
- 2019-0045-NaN-0000
- Page Start:
- 84
- Page End:
- 91
- Publication Date:
- 2019-04-21
- Subjects:
- DPIs -- Aerolizer -- inhalation flow -- the number of inhalations -- Diskus -- Inhalation volume -- healthy subjects -- COPD
Lungs -- Periodicals
Lungs -- Diseases -- Periodicals
Lung Diseases
Lung -- physiology
Respiratory System
616.24 - Journal URLs:
- http://informahealthcare.com/loi/elu ↗
http://www.tandfonline.com/loi/ielu20 ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/01902148.2019.1621408 ↗
- Languages:
- English
- ISSNs:
- 0190-2148
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3839.440000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16311.xml