Combustion characteristics and thermal performance of premixed hydrogen-air in a two-rearward-step micro tube. (15th May 2019)
- Record Type:
- Journal Article
- Title:
- Combustion characteristics and thermal performance of premixed hydrogen-air in a two-rearward-step micro tube. (15th May 2019)
- Main Title:
- Combustion characteristics and thermal performance of premixed hydrogen-air in a two-rearward-step micro tube
- Authors:
- Peng, Qingguo
Wu, Yifeng
E, Jiaqiang
Yang, Wenming
Xu, Hongpeng
Li, Zhenwei - Abstract:
- Graphical abstract: Highlights: Two rearward-steps and various inlet shapes are used to enhance the flame stabilization. Flame location, OH radical and gas temperature distributions are verified. Power output and radiation efficiency in two different combustors are compared. Abstract: Combustion characteristics, flame location and thermal performance of premixed hydrogen-air combustion in two combustors with different outer diameters (OD = 4 mm and OD = 5 mm) are investigated and compared. In order to enhance the flame stabilization and improve the efficiency, the micro combustors are presented with two rearward-steps and various inlet shapes. Verified with experimental tests, a three-dimensional numerical model has been employed to assess the flame location, OH radical and gas temperature distributions. It is observed that the flame location and thermal performance are significantly affected by the structure of the micro combustor. The results indicate that a properly stepped/flared inlet section contributes to the ignition and enhances the preheating of the unburned reactants. The heat recirculation zone behind the rearward-step provides a suitable location for the flame anchoring. In addition, a high and uniform outer wall temperature distribution is beneficial for the efficiency improvement and system application. The combustor with a small size obtains a higher wall temperature and is more sensitive to the change of combustion chamber. However, the combustors withGraphical abstract: Highlights: Two rearward-steps and various inlet shapes are used to enhance the flame stabilization. Flame location, OH radical and gas temperature distributions are verified. Power output and radiation efficiency in two different combustors are compared. Abstract: Combustion characteristics, flame location and thermal performance of premixed hydrogen-air combustion in two combustors with different outer diameters (OD = 4 mm and OD = 5 mm) are investigated and compared. In order to enhance the flame stabilization and improve the efficiency, the micro combustors are presented with two rearward-steps and various inlet shapes. Verified with experimental tests, a three-dimensional numerical model has been employed to assess the flame location, OH radical and gas temperature distributions. It is observed that the flame location and thermal performance are significantly affected by the structure of the micro combustor. The results indicate that a properly stepped/flared inlet section contributes to the ignition and enhances the preheating of the unburned reactants. The heat recirculation zone behind the rearward-step provides a suitable location for the flame anchoring. In addition, a high and uniform outer wall temperature distribution is beneficial for the efficiency improvement and system application. The combustor with a small size obtains a higher wall temperature and is more sensitive to the change of combustion chamber. However, the combustors with OD = 5 mm gains the better flame stability and working performance with a higher power output, radiation efficiency and system efficiency at a higher mass flow rate. Moreover, the power output and system efficiency of the combustor with two rearward-steps are 2 times higher than that with one step. … (more)
- Is Part Of:
- Applied energy. Volume 242(2019)
- Journal:
- Applied energy
- Issue:
- Volume 242(2019)
- Issue Display:
- Volume 242, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 242
- Issue:
- 2019
- Issue Sort Value:
- 2019-0242-2019-0000
- Page Start:
- 424
- Page End:
- 438
- Publication Date:
- 2019-05-15
- Subjects:
- Micro combustion -- Rearward-step -- Flame location -- Thermal performance -- Efficiency
Power (Mechanics) -- Periodicals
Energy conservation -- Periodicals
Energy conversion -- Periodicals
621.042 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03062619 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apenergy.2019.03.137 ↗
- Languages:
- English
- ISSNs:
- 0306-2619
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16304.xml