Effects of downward-facing surface type and inclination on critical heat flux during pool boiling. (March 2018)
- Record Type:
- Journal Article
- Title:
- Effects of downward-facing surface type and inclination on critical heat flux during pool boiling. (March 2018)
- Main Title:
- Effects of downward-facing surface type and inclination on critical heat flux during pool boiling
- Authors:
- Gong, H.
Wang, L.
Khan, A.R.
Erkan, N.
Okamoto, K. - Abstract:
- Highlights: Boiling heat transfer for CHF increased by application of honeycomb surface. Porous honeycomb further enhances CHF performance due to water supply through porous surface. Increased inclination facilitates bubble removal ability, providing more room for water supply. Bubble removal ability is key factor affecting CHF in honeycomb case. Abstract: The effectiveness of ex-vessel cooling systems in response to severe nuclear reactor accidents is attributable, in part, to the critical heat flux (CHF). As such, CHF enhancement has been the focus of significant research. Prior studies have demonstrated that porous and specifically, honeycomb surfaces can increase the CHF. In this study, we compared the CHF of bare- and various honeycomb downward-facing surfaces during pool boiling. In addition, we investigated the effects of surface inclination on the CHF. The results indicated that the honeycomb surfaces had higher CHF values than the bare surface. The honeycomb surfaces provided separate water supply and bubble removal paths, which decreased the liquid–vapor counterflow resistance and increased the water supply to the heating surface for cooling. The porous honeycomb surfaces (with 5-, 20-, and 100-μm pores) had higher CHF values than the honeycomb surface with no pores (with 0-μm pores). Among the different porous surfaces, the CHF values were equivalent. With respect to inclination, the results indicated that the CHF increased as surface inclination increased forHighlights: Boiling heat transfer for CHF increased by application of honeycomb surface. Porous honeycomb further enhances CHF performance due to water supply through porous surface. Increased inclination facilitates bubble removal ability, providing more room for water supply. Bubble removal ability is key factor affecting CHF in honeycomb case. Abstract: The effectiveness of ex-vessel cooling systems in response to severe nuclear reactor accidents is attributable, in part, to the critical heat flux (CHF). As such, CHF enhancement has been the focus of significant research. Prior studies have demonstrated that porous and specifically, honeycomb surfaces can increase the CHF. In this study, we compared the CHF of bare- and various honeycomb downward-facing surfaces during pool boiling. In addition, we investigated the effects of surface inclination on the CHF. The results indicated that the honeycomb surfaces had higher CHF values than the bare surface. The honeycomb surfaces provided separate water supply and bubble removal paths, which decreased the liquid–vapor counterflow resistance and increased the water supply to the heating surface for cooling. The porous honeycomb surfaces (with 5-, 20-, and 100-μm pores) had higher CHF values than the honeycomb surface with no pores (with 0-μm pores). Among the different porous surfaces, the CHF values were equivalent. With respect to inclination, the results indicated that the CHF increased as surface inclination increased for both bare and honeycomb surfaces. The increased surface inclination facilitated bubble removal and again increased the water supply to the heating surface for cooling. Thus, the water supply and bubble removal capacities are two underlying factors affecting the CHF. The CHF (and ultimately ex-vessel cooling system effectiveness) is determined by the limiting water supply or bubble removal capacities. In this study, the bubble removal capacity was consistently the limiting factor for determining the CHF. … (more)
- Is Part Of:
- Annals of nuclear energy. Volume 113(2018)
- Journal:
- Annals of nuclear energy
- Issue:
- Volume 113(2018)
- Issue Display:
- Volume 113, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 113
- Issue:
- 2018
- Issue Sort Value:
- 2018-0113-2018-0000
- Page Start:
- 344
- Page End:
- 352
- Publication Date:
- 2018-03
- Subjects:
- Critical heat flux -- Downward-facing pool boiling -- Honeycomb surface -- Inclined surface -- Water supply -- Bubble removal
Nuclear energy -- Periodicals
Nuclear engineering -- Periodicals
621.4805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03064549 ↗
http://catalog.hathitrust.org/api/volumes/oclc/2243298.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.anucene.2017.11.048 ↗
- Languages:
- English
- ISSNs:
- 0306-4549
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1043.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16294.xml