Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification. (29th October 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification. (29th October 2015)
- Main Title:
- Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification
- Authors:
- Palmer, Antony L
Dimitriadis, Alexis
Nisbet, Andrew
Clark, Catharine H - Abstract:
- Abstract: There is renewed interest in film dosimetry for the verification of dose delivery of complex treatments, particularly small fields, compared to treatment planning system calculations. A new radiochromic film, Gafchromic EBT-XD, is available for high-dose treatment verification and we present the first published evaluation of its use. We evaluate the new film for MV photon dosimetry, including calibration curves, performance with single- and triple-channel dosimetry, and comparison to existing EBT3 film. In the verification of a typical 25 Gy stereotactic radiotherapy (SRS) treatment, compared to TPS planned dose distribution, excellent agreement was seen with EBT-XD using triple-channel dosimetry, in isodose overlay, maximum 1.0 mm difference over 200–2400 cGy, and gamma evaluation, mean passing rate 97% at 3% locally-normalised, 1.5 mm criteria. In comparison to EBT3, EBT-XD gave improved evaluation results for the SRS-plan, had improved calibration curve gradients at high doses, and had reduced lateral scanner effect. The dimensions of the two films are identical. The optical density of EBT-XD is lower than EBT3 for the same dose. The effective atomic number for both may be considered water-equivalent in MV radiotherapy. We have validated the use of EBT-XD for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison.
- Is Part Of:
- Physics in medicine & biology. Volume 60:Number 22(2015:Nov.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 60:Number 22(2015:Nov.)
- Issue Display:
- Volume 60, Issue 22 (2015)
- Year:
- 2015
- Volume:
- 60
- Issue:
- 22
- Issue Sort Value:
- 2015-0060-0022-0000
- Page Start:
- 8741
- Page End:
- 8752
- Publication Date:
- 2015-10-29
- Subjects:
- film -- radiochromic -- EBT3 -- EBT-XD -- audit -- dosimetry -- SRS
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/60/22/8741 ↗
- Languages:
- English
- ISSNs:
- 0031-9155