Superparamagnetic iron oxide-enhanced MRI at 3 T for accurate axillary staging in breast cancer. Issue 1 (17th November 2015)
- Record Type:
- Journal Article
- Title:
- Superparamagnetic iron oxide-enhanced MRI at 3 T for accurate axillary staging in breast cancer. Issue 1 (17th November 2015)
- Main Title:
- Superparamagnetic iron oxide-enhanced MRI at 3 T for accurate axillary staging in breast cancer
- Authors:
- Motomura, K
Izumi, T
Tateishi, S
Tamaki, Y
Ito, Y
Horinouchi, T
Nakanishi, K - Abstract:
- Abstract: Background: The aim of this study was to evaluate whether MRI at 3 T with superparamagnetic iron oxide (SPIO) enhancement is an accurate and useful method for detecting metastases in sentinel nodes identified by CT-lymphography (CT-LG) in patients with breast cancer. The results were compared with those obtained using CT-LG alone and diagnosing metastasis according to size criteria. Methods: Patients with clinically node-negative breast cancer were included. Sentinel nodes identified by CT-LG were evaluated prospectively using SPIO-enhanced MRI at 3 T. Sentinel node size was measured on CT-LG, and a node larger than 5 mm in short-axis diameter was considered metastatic. Sentinel nodes localized by CT-LG were removed, and imaging results and histopathological findings were compared. Results: Sentinel nodes were identified successfully by CT-LG in 69 (99 per cent) of 70 patients. All 19 patients with a finding of metastasis in sentinel nodes at pathology were also shown to have metastases on MRI. Forty-eight of 50 patients with non-metastatic sentinel nodes diagnosed at pathology were classified as having non-metastatic nodes on MRI. On a patient-by-patient basis, the sensitivity, specificity and accuracy of MRI for the diagnosis of sentinel node metastases were 100, 96 and 97 per cent; respective values for CT-LG were 79, 56 and 62 per cent. The specificity and accuracy of MRI were superior to those of CT-LG ( P < 0·001 and P = 0·002 respectively). Conclusion:Abstract: Background: The aim of this study was to evaluate whether MRI at 3 T with superparamagnetic iron oxide (SPIO) enhancement is an accurate and useful method for detecting metastases in sentinel nodes identified by CT-lymphography (CT-LG) in patients with breast cancer. The results were compared with those obtained using CT-LG alone and diagnosing metastasis according to size criteria. Methods: Patients with clinically node-negative breast cancer were included. Sentinel nodes identified by CT-LG were evaluated prospectively using SPIO-enhanced MRI at 3 T. Sentinel node size was measured on CT-LG, and a node larger than 5 mm in short-axis diameter was considered metastatic. Sentinel nodes localized by CT-LG were removed, and imaging results and histopathological findings were compared. Results: Sentinel nodes were identified successfully by CT-LG in 69 (99 per cent) of 70 patients. All 19 patients with a finding of metastasis in sentinel nodes at pathology were also shown to have metastases on MRI. Forty-eight of 50 patients with non-metastatic sentinel nodes diagnosed at pathology were classified as having non-metastatic nodes on MRI. On a patient-by-patient basis, the sensitivity, specificity and accuracy of MRI for the diagnosis of sentinel node metastases were 100, 96 and 97 per cent; respective values for CT-LG were 79, 56 and 62 per cent. The specificity and accuracy of MRI were superior to those of CT-LG ( P < 0·001 and P = 0·002 respectively). Conclusion: SPIO-enhanced MRI at 3 T is useful for accurate diagnosis of metastatic sentinel nodes, indicating that sentinel node biopsy may be avoided in patients with breast cancer who have non-metastatic sentinel nodes on imaging. Abstract : Imaging replaces sentinel node biopsy … (more)
- Is Part Of:
- British journal of surgery. Volume 103:Issue 1(2016)
- Journal:
- British journal of surgery
- Issue:
- Volume 103:Issue 1(2016)
- Issue Display:
- Volume 103, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 103
- Issue:
- 1
- Issue Sort Value:
- 2016-0103-0001-0000
- Page Start:
- 60
- Page End:
- 69
- Publication Date:
- 2015-11-17
- Subjects:
- Surgery -- Periodicals
617.005 - Journal URLs:
- http://www.bjs.co.uk/bjsCda/cda/microHome.do ↗
https://academic.oup.com/bjs# ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/bjs.10040 ↗
- Languages:
- English
- ISSNs:
- 0007-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2325.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16254.xml