Monitoring Results after 36 Ktonnes of Deep CO2 Injection at the Aquistore CO2 Storage Site, Saskatchewan, Canada. (July 2017)
- Record Type:
- Journal Article
- Title:
- Monitoring Results after 36 Ktonnes of Deep CO2 Injection at the Aquistore CO2 Storage Site, Saskatchewan, Canada. (July 2017)
- Main Title:
- Monitoring Results after 36 Ktonnes of Deep CO2 Injection at the Aquistore CO2 Storage Site, Saskatchewan, Canada
- Authors:
- White, Don
Harris, Kyle
Roach, Lisa
Roberts, Brian
Worth, Kyle
Stork, Anna
Nixon, Christopher
Schmitt, Douglas
Daley, Tom
Samson, Claire - Abstract:
- Abstract: The Aquistore CO2 Storage Site is located in southeastern Saskatchewan, Canada. CO2 is injected into a brine-filled sandstone formation at ∼3200 m depth immediately above the Precambrian basement. Sustained injection rates of 400-600 tonnes/day were achieved at the site starting in the fall of 2015 with a total of 88 ktonnes having been injected by the end of September, 2016. Seismic monitoring methods have been employed to track the subsurface CO2 plume and to record any injection-induced seismicity. Passive seismic monitoring is being conducted using two orthogonal arrays of short-period geophones, 3 broadband seismographs, and an array of downhole geophones. No significant injection-related seismicity (Mw > -1) has been detected during the first 17 months of CO2 injection. The first post-injection time-lapse 3D seismic surveys (surface and VSP) were conducted at the site in February, 2016. The VSP data were acquired with a distributed acoustic sensing system using a 2750 m casing-conveyed optical fibre cable in the observation well. 3D seismic modelling of fluid flow simulations in conjunction with seismic repeatability estimates obtained from field data indicate that the time-lapse VSP should be capable of imaging the CO2 plume after a total injection of ∼30 ktonnes. In addition, this first monitor survey tests the ability of surface seismic data acquired with a sparse permanent array to detect or image the CO2 plume after limited injection. Time-lapse loggingAbstract: The Aquistore CO2 Storage Site is located in southeastern Saskatchewan, Canada. CO2 is injected into a brine-filled sandstone formation at ∼3200 m depth immediately above the Precambrian basement. Sustained injection rates of 400-600 tonnes/day were achieved at the site starting in the fall of 2015 with a total of 88 ktonnes having been injected by the end of September, 2016. Seismic monitoring methods have been employed to track the subsurface CO2 plume and to record any injection-induced seismicity. Passive seismic monitoring is being conducted using two orthogonal arrays of short-period geophones, 3 broadband seismographs, and an array of downhole geophones. No significant injection-related seismicity (Mw > -1) has been detected during the first 17 months of CO2 injection. The first post-injection time-lapse 3D seismic surveys (surface and VSP) were conducted at the site in February, 2016. The VSP data were acquired with a distributed acoustic sensing system using a 2750 m casing-conveyed optical fibre cable in the observation well. 3D seismic modelling of fluid flow simulations in conjunction with seismic repeatability estimates obtained from field data indicate that the time-lapse VSP should be capable of imaging the CO2 plume after a total injection of ∼30 ktonnes. In addition, this first monitor survey tests the ability of surface seismic data acquired with a sparse permanent array to detect or image the CO2 plume after limited injection. Time-lapse logging is being conducted on a regular basis to provide in situ measurement of the change in seismic velocity associated with changes in CO2 saturation. … (more)
- Is Part Of:
- Energy procedia. Volume 114(2017)
- Journal:
- Energy procedia
- Issue:
- Volume 114(2017)
- Issue Display:
- Volume 114, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 114
- Issue:
- 2017
- Issue Sort Value:
- 2017-0114-2017-0000
- Page Start:
- 4056
- Page End:
- 4061
- Publication Date:
- 2017-07
- Subjects:
- storage -- monitoring -- seismic -- 4D
Power resources -- Congresses
Power resources -- Periodicals
Power resources
Conference proceedings
Periodicals
333.7905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18766102 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.egypro.2017.03.1546 ↗
- Languages:
- English
- ISSNs:
- 1876-6102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.729700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16250.xml