Ratio of arterial blood pressures at borders of window surrounding systolic peak indicates patent ductus arteriosus in preterm infants. (4th February 2021)
- Record Type:
- Journal Article
- Title:
- Ratio of arterial blood pressures at borders of window surrounding systolic peak indicates patent ductus arteriosus in preterm infants. (4th February 2021)
- Main Title:
- Ratio of arterial blood pressures at borders of window surrounding systolic peak indicates patent ductus arteriosus in preterm infants
- Authors:
- Bennis, Frank C
Andriessen, Peter
van Pul, Carola
Kramer, Boris W
Delhaas, Tammo - Abstract:
- Abstract: Objective. Presence of a patent ductus arteriosus (PDA) in neonates is assessed by echocardiography. Echocardiographic assessment has disadvantages, primarily its discontinuous nature. We hypothesize that the continuously measured ratio of arterial blood pressures (ABP) at the borders of a window surrounding the systolic peak ratio discriminates non-PDA from PDA patients. Approach. Preterm infants (gestational age <32 weeks) with and without PDA were included. Patients were divided into controls ( n = 8) and PDA patients ( n = 22), the latter with a subset of patients with closed PDA after three doses Ibuprofen ( n = 10). For each patient, a six-hour ABP segment from 12 AM to 6 AM on the day of echocardiographic assessment patency or closure of the DA was selected. The mean ratio of the ABP values a samples before and p samples after the systolic peak ( R ABP ) was calculated for each segment. If R ABP < 1, the patient was predicted to have a PDA. The a and p with the least misclassifications were selected (−64 and +104 ms). Main results. R ABP was significantly lower in PDA patients (median 0.95, IQR 0.06) compared to controls (median 1.05, IQR 0.10; p = 0.0024). R ABP correctly predicted 19 out of 22 patients (86.4%) and six out of eight controls (75%). R ABP increased after closure in nine out of 10 patients (median 1.01, IQR 0.04; p = 0. 0182). Significance. R ABP may discriminate preterm PDA patients from non-PDA patients and can be calculatedAbstract: Objective. Presence of a patent ductus arteriosus (PDA) in neonates is assessed by echocardiography. Echocardiographic assessment has disadvantages, primarily its discontinuous nature. We hypothesize that the continuously measured ratio of arterial blood pressures (ABP) at the borders of a window surrounding the systolic peak ratio discriminates non-PDA from PDA patients. Approach. Preterm infants (gestational age <32 weeks) with and without PDA were included. Patients were divided into controls ( n = 8) and PDA patients ( n = 22), the latter with a subset of patients with closed PDA after three doses Ibuprofen ( n = 10). For each patient, a six-hour ABP segment from 12 AM to 6 AM on the day of echocardiographic assessment patency or closure of the DA was selected. The mean ratio of the ABP values a samples before and p samples after the systolic peak ( R ABP ) was calculated for each segment. If R ABP < 1, the patient was predicted to have a PDA. The a and p with the least misclassifications were selected (−64 and +104 ms). Main results. R ABP was significantly lower in PDA patients (median 0.95, IQR 0.06) compared to controls (median 1.05, IQR 0.10; p = 0.0024). R ABP correctly predicted 19 out of 22 patients (86.4%) and six out of eight controls (75%). R ABP increased after closure in nine out of 10 patients (median 1.01, IQR 0.04; p = 0. 0182). Significance. R ABP may discriminate preterm PDA patients from non-PDA patients and can be calculated continuously from clinical data measured during standard of care. … (more)
- Is Part Of:
- Physiological measurement. Volume 42:Number 1(2021)
- Journal:
- Physiological measurement
- Issue:
- Volume 42:Number 1(2021)
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02-04
- Subjects:
- patent ductus arteriosus -- neonatal care -- arterial blood pressure -- parameter -- continuous
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/abd5aa ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16230.xml