Ultrasensitive measurement of gas refractive index based on cascaded Mach–Zehnder interferometers and Vernier effect. (2nd June 2021)
- Record Type:
- Journal Article
- Title:
- Ultrasensitive measurement of gas refractive index based on cascaded Mach–Zehnder interferometers and Vernier effect. (2nd June 2021)
- Main Title:
- Ultrasensitive measurement of gas refractive index based on cascaded Mach–Zehnder interferometers and Vernier effect
- Authors:
- Li, Jun
Cheng, Hongwei
Lin, Hongfeng
Li, Hao
Zhou, Ai - Abstract:
- Abstract: An ultrasensitive gas refractive index (RI) sensor based on fiber Mach–Zehnder interferometers (MZIs) and Vernier effect is proposed and demonstrated. The sensor consists of two cascaded fiber MZIs, one of which serves as a reference unit and is fabricated by fusion splicing a section of symmetrical side-hole fiber in between two short pieces of multi-mode fiber (MMF); the other acts as a sensing unit, which is composed of a section of tapered single-mode fiber sandwiched between two sections of MMF. The two MZIs are designed to have similar free spectral range for generating optical Vernier effect. Because the two MZIs have different responses to external RI, the RI-related Vernier effect can be obtained and the RI sensitivity can be improved, while there is no temperature sensitivity enhancement because the two MZIs have the same response to temperature. Thus the structure has low temperature crosstalk when obtaining high RI sensitivity. Experimental results show that the gas RI sensor has an ultrahigh sensitivity of 4.2 × 10 4 nm RIU −1 (RI unit). At the same time, the temperature cross-sensitivity is only 2.2 × 10 −6 RIU °C −1 . Therefore, the proposed sensor has potential applications for modern gas concentration monitoring in a large dynamic range.
- Is Part Of:
- Measurement science & technology. Volume 32:Number 9(2021)
- Journal:
- Measurement science & technology
- Issue:
- Volume 32:Number 9(2021)
- Issue Display:
- Volume 32, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 9
- Issue Sort Value:
- 2021-0032-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06-02
- Subjects:
- gas refractive index -- Mach–Zehnder interferometer -- Vernier effect -- high sensitivity
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/abe081 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: