Applicability of displacement ventilation and impinging jet ventilation system to heating operation. Issue 2 (18th March 2021)
- Record Type:
- Journal Article
- Title:
- Applicability of displacement ventilation and impinging jet ventilation system to heating operation. Issue 2 (18th March 2021)
- Main Title:
- Applicability of displacement ventilation and impinging jet ventilation system to heating operation
- Authors:
- Yamasawa, Haruna
Kobayashi, Tomohiro
Yamanaka, Toshio
Choi, Narae
Cehlin, Mathias
Ameen, Arman - Abstract:
- Abstract: This study aims to acquire an understanding of the fundamental feature of IJV and DV under heating operation. Full‐scale experiments were conducted under these two different systems and supply air conditions along with temperature distribution and ventilation effectiveness. A wall surface of the test room was cooled as a heating load, and heating elements simulating occupants were located as internal heat load and contaminant emission source. Three cases of supply temperature were tested and the flow rate was also varied correspondingly. The position of the supply terminal was also changed to see its effect on heating performance, that is, mounted on the interior/exterior wall. For DV, the temperature/contaminant distribution differed significantly depending on the supply conditions, while that of IJV remained almost the same as a perfect mixing condition. Generally, IJV can achieve better temperature distribution compared to DV; however, the ventilation effectiveness of DV was superior to that of IJV with large supply flow rate. The correlation between the Archimedes number based on supply conditions and indices expressing local temperature and ventilation effectiveness is obtained. For IJV, the position of the terminal was found to have a larger impact on air distribution than the supply flow rate, while the opposite feature was obtained for DV. Abstract : For DV, the temperature and contaminant distribution differed significantly depending on the supplyAbstract: This study aims to acquire an understanding of the fundamental feature of IJV and DV under heating operation. Full‐scale experiments were conducted under these two different systems and supply air conditions along with temperature distribution and ventilation effectiveness. A wall surface of the test room was cooled as a heating load, and heating elements simulating occupants were located as internal heat load and contaminant emission source. Three cases of supply temperature were tested and the flow rate was also varied correspondingly. The position of the supply terminal was also changed to see its effect on heating performance, that is, mounted on the interior/exterior wall. For DV, the temperature/contaminant distribution differed significantly depending on the supply conditions, while that of IJV remained almost the same as a perfect mixing condition. Generally, IJV can achieve better temperature distribution compared to DV; however, the ventilation effectiveness of DV was superior to that of IJV with large supply flow rate. The correlation between the Archimedes number based on supply conditions and indices expressing local temperature and ventilation effectiveness is obtained. For IJV, the position of the terminal was found to have a larger impact on air distribution than the supply flow rate, while the opposite feature was obtained for DV. Abstract : For DV, the temperature and contaminant distribution differed significantly depending on the supply conditions, while that of IJV remained almost the same. IJV can achieve better temperature distribution compared to DV, and it is almost the same as the mixing condition. However, depending on the supply condition, the ventilation effectiveness of DV was superior to that of IJV in some cases. … (more)
- Is Part Of:
- Japan architectural review. Volume 4:Issue 2(2021)
- Journal:
- Japan architectural review
- Issue:
- Volume 4:Issue 2(2021)
- Issue Display:
- Volume 4, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 4
- Issue:
- 2
- Issue Sort Value:
- 2021-0004-0002-0000
- Page Start:
- 403
- Page End:
- 416
- Publication Date:
- 2021-03-18
- Subjects:
- impinging jet ventilation -- displacement ventilation -- space heating -- ventilation effectiveness -- full‐scale experiment
Building -- Periodicals
Building -- Japan -- Periodicals
Architectural design -- Periodicals
690 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2475-8876/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/2475-8876.12220 ↗
- Languages:
- English
- ISSNs:
- 2475-8876
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16230.xml