Effect of Supply Cooling Oil Temperature in Structural Cooling Channels on the Positioning Accuracy of Machine Tools. (4th November 2019)
- Record Type:
- Journal Article
- Title:
- Effect of Supply Cooling Oil Temperature in Structural Cooling Channels on the Positioning Accuracy of Machine Tools. (4th November 2019)
- Main Title:
- Effect of Supply Cooling Oil Temperature in Structural Cooling Channels on the Positioning Accuracy of Machine Tools
- Authors:
- Li, K.-Y.
Luo, W.-J.
Yang, M.-H.
Hong, X.-H.
Luo, S.-J.
Chen, C.-N. - Abstract:
- Abstract : In this study, the thermal deformation of a machine tool structure due to the heat generated during operation was analyzed, and embedded cooling channels were applied to exchange the heat generated during the operation to achieve thermal error suppression. Then, the finite volume method was used to simulate the effect of cooling oil temperature on thermal deformation, and the effect of thermal suppression was experimentally studied using a feed system combined with a cooler to improve the positioning accuracy of the machine tool. In this study, the supply oil temperature in the structural cooling channels was found to significantly affect the position accuracy of the moving table and moving carrier. If the supply oil temperature in the cooling channels is consistent with the operational ambient temperature, the position accuracy of the moving table in the Y direction and the moving carrier in the X and Z directions has the best performance under different feed rates. From the thermal suppression experiments of the embedded cooling channels, the positioning accuracy of the feed system can be improved by approximately 25.5 % during the dynamic feeding process. Furthermore, when the hydrostatic guideway is cooled and dynamic feeding is conducted, positioning accuracy can be improved by up to 47.8 %. The machining accuracy can be improved by approximately 60 % on average by using the embedded cooling channels in this study. Therefore, thermal suppression by theAbstract : In this study, the thermal deformation of a machine tool structure due to the heat generated during operation was analyzed, and embedded cooling channels were applied to exchange the heat generated during the operation to achieve thermal error suppression. Then, the finite volume method was used to simulate the effect of cooling oil temperature on thermal deformation, and the effect of thermal suppression was experimentally studied using a feed system combined with a cooler to improve the positioning accuracy of the machine tool. In this study, the supply oil temperature in the structural cooling channels was found to significantly affect the position accuracy of the moving table and moving carrier. If the supply oil temperature in the cooling channels is consistent with the operational ambient temperature, the position accuracy of the moving table in the Y direction and the moving carrier in the X and Z directions has the best performance under different feed rates. From the thermal suppression experiments of the embedded cooling channels, the positioning accuracy of the feed system can be improved by approximately 25.5 % during the dynamic feeding process. Furthermore, when the hydrostatic guideway is cooled and dynamic feeding is conducted, positioning accuracy can be improved by up to 47.8 %. The machining accuracy can be improved by approximately 60 % on average by using the embedded cooling channels in this study. Therefore, thermal suppression by the cooling channels in this study can not only effectively improve the positioning accuracy but also enhance machining accuracy, proving that the method is effective for enhancing machine tool accuracy. … (more)
- Is Part Of:
- Journal of mechanics. Volume 35:Number 6(2019)
- Journal:
- Journal of mechanics
- Issue:
- Volume 35:Number 6(2019)
- Issue Display:
- Volume 35, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 35
- Issue:
- 6
- Issue Sort Value:
- 2019-0035-0006-0000
- Page Start:
- 887
- Page End:
- 900
- Publication Date:
- 2019-11-04
- Subjects:
- Thermal deformation -- Thermal suppression -- Structure cooling -- Oil temperature
Mechanics, Analytic -- Periodicals
Mechanics -- Periodicals
620.1005 - Journal URLs:
- https://academic.oup.com/jom ↗
http://journals.cambridge.org/action/displayJournal?jid=JOM ↗
http://www.oxfordjournals.org/ ↗ - DOI:
- 10.1017/jmech.2019.29 ↗
- Languages:
- English
- ISSNs:
- 1727-7191
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16236.xml