Electrochemical safety limits for clinical stimulation investigated using depth and strip electrodes in the pig brain. (4th June 2021)
- Record Type:
- Journal Article
- Title:
- Electrochemical safety limits for clinical stimulation investigated using depth and strip electrodes in the pig brain. (4th June 2021)
- Main Title:
- Electrochemical safety limits for clinical stimulation investigated using depth and strip electrodes in the pig brain
- Authors:
- Vatsyayan, Ritwik
Cleary, Daniel
Martin, Joel R
Halgren, Eric
Dayeh, Shadi A - Abstract:
- Abstract: Objective . Diagnostic and therapeutic electrical stimulation are increasingly utilized with the rise of neuromodulation devices. However, systematic investigations that depict the practical clinical stimulation paradigms (bipolar, two-electrode configuration) to determine the safety limits are currently lacking. Further, safe charge densities that were classically determined from conical sharp electrodes are generalized for cylindrical (depth) and flat (surface grid) electrodes completely ignoring geometric factors that govern current spreading and trajectories in tissue. Approach . This work reports the first investigations comparing stimulation limits for clinically used electrodes in two mediums: in benchtop experiments in saline and in vivo in a single acute experiment in the pig brain. We experimentally determine the geometric factors, the water electrolysis windows, and the current safety limits from voltage transients, for the sEEG, depth and surface strip electrodes in both mediums. Using four-electrode and three-electrode configuration measurements and comprehensive circuit models that accurately depict our measurements, we delineate the various elements of the stimulation medium, including the tissue-electrode interface impedance spectra, the medium impedance and the bias-dependent change in the interface impedance as a function of stimulation parameters. Main results . The results of our systematics studies suggest that safe currents in clinical bipolarAbstract: Objective . Diagnostic and therapeutic electrical stimulation are increasingly utilized with the rise of neuromodulation devices. However, systematic investigations that depict the practical clinical stimulation paradigms (bipolar, two-electrode configuration) to determine the safety limits are currently lacking. Further, safe charge densities that were classically determined from conical sharp electrodes are generalized for cylindrical (depth) and flat (surface grid) electrodes completely ignoring geometric factors that govern current spreading and trajectories in tissue. Approach . This work reports the first investigations comparing stimulation limits for clinically used electrodes in two mediums: in benchtop experiments in saline and in vivo in a single acute experiment in the pig brain. We experimentally determine the geometric factors, the water electrolysis windows, and the current safety limits from voltage transients, for the sEEG, depth and surface strip electrodes in both mediums. Using four-electrode and three-electrode configuration measurements and comprehensive circuit models that accurately depict our measurements, we delineate the various elements of the stimulation medium, including the tissue-electrode interface impedance spectra, the medium impedance and the bias-dependent change in the interface impedance as a function of stimulation parameters. Main results . The results of our systematics studies suggest that safe currents in clinical bipolar stimulation determined in vivo can be as much as 24 times smaller than those determined from benchtop experiments (for depth electrodes at a 1 ms pulse duration). Our detailed circuit modeling attributes this drastic difference in safe limits to the greatly dissimilar electrode/tissue and electrode/saline impedances. Significance . We established the electrochemical safety limits for commonly used clinical electrodes in vivo and revealed by detailied electrochemical modeling how they differ from benchtop evaluation. We argue that electrochemical limits and currents are unique for each electrode, should be measured in vivo according to the protocols established in this work, and should be accounted for while setting the stimulation parameters for clinical applications including for chronic applications. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 18:Number 4(2021)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 18:Number 4(2021)
- Issue Display:
- Volume 18, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 18
- Issue:
- 4
- Issue Sort Value:
- 2021-0018-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06-04
- Subjects:
- stimulation -- brain -- clinical -- electrochemical -- safety -- limits -- electrode
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2552/ac038b ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16291.xml