Impact of proton dose calculation algorithms on the interplay effect in PBS proton based SBRT lung plans. (19th May 2021)
- Record Type:
- Journal Article
- Title:
- Impact of proton dose calculation algorithms on the interplay effect in PBS proton based SBRT lung plans. (19th May 2021)
- Main Title:
- Impact of proton dose calculation algorithms on the interplay effect in PBS proton based SBRT lung plans
- Authors:
- Rana, Suresh
Rosenfeld, Anatoly B - Abstract:
- Abstract: Purpose . The purpose of the current study was to investigate the impact of RayStation analytical pencil beam (APB) and Monte Carlo (MC) algorithms on the interplay effect in pencil beam scanning (PBS) proton-based stereotactic body radiation therapy (SBRT) lung plans. Methods . The current in-silico planning study was designed for a total dose of 5000 cGy(RBE) with a fractional dose of 1000 cGy(RBE). First, three sets of nominal plans were generated for each patient: (a) APB optimization followed by APB dose calculation (PB-PB), (b) APB optimization followed by MC dose calculation (PB-MC), and (c) MC optimization followed by MC dose calculation (MC-MC). Second, for each patient, two sets of volumetric repainting plans (five repaintings) – PB-MCVR5 and MC-MCVR5 were generated based on PB-MC and MC-MC, respectively. Dosimetric differences between APB and MC algorithms were calculated on the nominal and interplay dose-volume-histograms (DVHs). Results . Interplay evaluation in non-volumetric repainting plans showed that APB algorithm overestimated the target coverage by up to 8.4% for D95% and 10.5% for D99%, whereas in volumetric repainting plans, APB algorithm overestimated by up to 5.3% for D95% and 7.0% for D99% . Interplay results for MC calculations showed a decrease in D95% and D99% by average differences of 3.5% and 4.7%, respectively, in MC-MC plans and by 1.8% and 3.0% in MC-MCVR5 plans. Conclusion . In PBS proton-based SBRT lung plans, the combination ofAbstract: Purpose . The purpose of the current study was to investigate the impact of RayStation analytical pencil beam (APB) and Monte Carlo (MC) algorithms on the interplay effect in pencil beam scanning (PBS) proton-based stereotactic body radiation therapy (SBRT) lung plans. Methods . The current in-silico planning study was designed for a total dose of 5000 cGy(RBE) with a fractional dose of 1000 cGy(RBE). First, three sets of nominal plans were generated for each patient: (a) APB optimization followed by APB dose calculation (PB-PB), (b) APB optimization followed by MC dose calculation (PB-MC), and (c) MC optimization followed by MC dose calculation (MC-MC). Second, for each patient, two sets of volumetric repainting plans (five repaintings) – PB-MCVR5 and MC-MCVR5 were generated based on PB-MC and MC-MC, respectively. Dosimetric differences between APB and MC algorithms were calculated on the nominal and interplay dose-volume-histograms (DVHs). Results . Interplay evaluation in non-volumetric repainting plans showed that APB algorithm overestimated the target coverage by up to 8.4% for D95% and 10.5% for D99%, whereas in volumetric repainting plans, APB algorithm overestimated by up to 5.3% for D95% and 7.0% for D99% . Interplay results for MC calculations showed a decrease in D95% and D99% by average differences of 3.5% and 4.7%, respectively, in MC-MC plans and by 1.8% and 3.0% in MC-MCVR5 plans. Conclusion . In PBS proton-based SBRT lung plans, the combination of APB algorithm and interplay effect reduced the target coverage. This may result in inferior local control. The use of MC algorithm for both optimization and final dose calculations in conjunction with the volumetric repainting technique yielded superior target coverage. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 7:Number 4(2021)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 7:Number 4(2021)
- Issue Display:
- Volume 7, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 7
- Issue:
- 4
- Issue Sort Value:
- 2021-0007-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-19
- Subjects:
- proton dose calculations -- analytical pencil beam algorithm -- Monte Carlo algorithm -- interplay effect -- SBRT lung cancer
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/abfea8 ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16222.xml