Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement. (January 2021)
- Record Type:
- Journal Article
- Title:
- Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement. (January 2021)
- Main Title:
- Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement
- Authors:
- Nai Fovino, Luca
Cipriani, Alberto
Fabris, Tommaso
Massussi, Mauro
Scotti, Andrea
Lorenzoni, Giulia
Guerra, Maria Chiara
Cardaioli, Francesco
Rodinò, Giulio
Matsuda, Yuji
Masiero, Giulia
Leoni, Loira
Zorzi, Alessandro
Fraccaro, Chiara
Tarantini, Giuseppe - Abstract:
- Abstract : Background: Conduction disturbances after transcatheter aortic valve replacement (TAVR) are often transient. Limited data exist on anatomic factors predisposing to pacemaker dependency after TAVR. We sought to assess the rate and the possible predictors of pacemaker dependency after TAVR. Methods: Consecutive patients undergoing pacemaker implantation up to 30 days after TAVR between May 2014 and September 2019 were included. Baseline electrocardiographic, computed tomography, and procedural characteristics were collected, including valve implantation depth and membranous septum length, an anatomic surrogate of the distance between the aortic annulus and the His bundle. Pacemaker dependency at 30 days and 1 year and all-cause mortality during follow-up were evaluated. Results: Of 728 TAVR patients, 112 (53.5% men; median age, 81 years) underwent pacemaker implantation after TAVR. Of these, 44.6% (50 of 112) were pacemaker dependent at 30 days and 46.7% (36 of 77) at 1 year. By multivariate analysis, independent predictors of 30-day pacemaker dependency included left ventricular outflow tract calcifications under the left coronary cusp (odds ratio, 5.69 [95% CI, 1.45–22.31]; P =0.013) and a difference between membranous septum length and implantation depth (ΔMSID) ≥3 mm (odds ratio, 7.58 [95% CI, 2.07–27.78]; P =0.002). Conversely, membranous septum length and implantation depth alone were not associated with pacemaker dependency (odds ratio, 0.79 [95% CI,Abstract : Background: Conduction disturbances after transcatheter aortic valve replacement (TAVR) are often transient. Limited data exist on anatomic factors predisposing to pacemaker dependency after TAVR. We sought to assess the rate and the possible predictors of pacemaker dependency after TAVR. Methods: Consecutive patients undergoing pacemaker implantation up to 30 days after TAVR between May 2014 and September 2019 were included. Baseline electrocardiographic, computed tomography, and procedural characteristics were collected, including valve implantation depth and membranous septum length, an anatomic surrogate of the distance between the aortic annulus and the His bundle. Pacemaker dependency at 30 days and 1 year and all-cause mortality during follow-up were evaluated. Results: Of 728 TAVR patients, 112 (53.5% men; median age, 81 years) underwent pacemaker implantation after TAVR. Of these, 44.6% (50 of 112) were pacemaker dependent at 30 days and 46.7% (36 of 77) at 1 year. By multivariate analysis, independent predictors of 30-day pacemaker dependency included left ventricular outflow tract calcifications under the left coronary cusp (odds ratio, 5.69 [95% CI, 1.45–22.31]; P =0.013) and a difference between membranous septum length and implantation depth (ΔMSID) ≥3 mm (odds ratio, 7.58 [95% CI, 2.07–27.78]; P =0.002). Conversely, membranous septum length and implantation depth alone were not associated with pacemaker dependency (odds ratio, 0.79 [95% CI, 0.60–1.05]; P =0.11 and odds ratio, 1.11 [95% CI, 0.99–1.24]; P =0.08). At a median follow-up of 28.1 (11.7–48.6) months, pacemaker-dependent patients did not show a worse survival ( P =0.26). Conclusions: Less than half of the patients undergoing pacemaker implantation after TAVR are pacemaker-dependent at midterm follow-up. ΔMSID ≥3 mm and the presence of left ventricular outflow tract calcifications under the left coronary cusp, but not membranous septum length nor implantation depth alone, are predictive of long-term pacemaker dependency after TAVR, thus influencing device selection and programming. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 14:Number 1(2021)
- Journal:
- Circulation
- Issue:
- Volume 14:Number 1(2021)
- Issue Display:
- Volume 14, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2021-0014-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- aortic valve -- atrioventricular block -- child -- follow-up studies -- multivariate analysis
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.120.009028 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16211.xml