Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors. (11th December 2020)
- Record Type:
- Journal Article
- Title:
- Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors. (11th December 2020)
- Main Title:
- Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
- Authors:
- Backis, A
Khaplanov, A
Al Jebali, R
Ammer, R
Apostolidis, I
Birch, J
Lai, C C
Deen, P P
Etxegarai, M
de Ruette, N
Freita Ramos, J
Förster, D F
Haettner, E
Hall-Wilton, R
Hamilton, D
Höglund, C
Kadletz, P M
Kanaki, K
Karnickis, E
Kirstein, O
Kolya, S
Kraujalyte, Z
Laloni, A
Livingston, K
Löhman, O
Maulerova, V
Mauritzon, N
Müller, F
Lopez Higuera, I
Richter, T
Robinson, L
Roth, R
Shetty, M
Taylor, J
Woracek, R
Xiong, W
… (more) - Abstract:
- Abstract: The boron-10 based multi-grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few µeV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ∼ µs short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of µs wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
- Is Part Of:
- Measurement science & technology. Volume 32:Number 3(2021)
- Journal:
- Measurement science & technology
- Issue:
- Volume 32:Number 3(2021)
- Issue Display:
- Volume 32, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2021-0032-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12-11
- Subjects:
- neutron detectors -- gaseous detectors -- boron-10 -- multi-grid detector -- helium-3 -- time resolution
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/abc63e ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16212.xml