Electrohydrodynamic spray applicator for homogenous application and reduced overspray of sunscreen. Issue 2 (20th July 2020)
- Record Type:
- Journal Article
- Title:
- Electrohydrodynamic spray applicator for homogenous application and reduced overspray of sunscreen. Issue 2 (20th July 2020)
- Main Title:
- Electrohydrodynamic spray applicator for homogenous application and reduced overspray of sunscreen
- Authors:
- Schleusener, Johannes
Schanzer, Sabine
Wille, Charlotte
Langen, Valentin
Richter, Heike
Lademann, Jürgen
Meinke, Martina C. - Abstract:
- Abstract: Background: The recommended amount of sunscreen by hand application (2 mg/cm 2 ) is in reality not achieved, which decreases the homogeneity and thereby the effective sun protection factor (SPF). Materials and Methods: The homogeneity of sunscreen applied by a newly developed spray applicator using an electrostatically charged aerosol, for which a hand rubbing of the formulation is not necessary, is evaluated. In vivo experiments were performed on the volar forearms of human volunteers using the spray applicator compared to the standardized hand application according to ISO 24444. Results: The distribution homogeneity was assessed qualitatively using in vivo laser scanning microscopy and quantitatively by absorption spectroscopy after tape stripping and by the standard deviation of multiple spatially displaced reflectance measurements for non‐invasive SPF determination below the minimal erythemal dose, which showed a significantly higher homogeneity by 20.9% after spray application compared to hand application. Conclusion: Non‐invasive SPF determination of multiple spatially displaced reflectance measurements was proven to be a suitable method for the non‐invasive determination of the sunscreen distribution homogeneity. Electrostatically charged spray application increased the sunscreen distribution homogeneity on the skin and can reduce the amount of overspray.
- Is Part Of:
- Skin research and technology. Volume 27:Issue 2(2021)
- Journal:
- Skin research and technology
- Issue:
- Volume 27:Issue 2(2021)
- Issue Display:
- Volume 27, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 2
- Issue Sort Value:
- 2021-0027-0002-0000
- Page Start:
- 191
- Page End:
- 200
- Publication Date:
- 2020-07-20
- Subjects:
- confocal laser scanning microscopy -- skin -- spectroscopy -- sun protection factor -- sunscreens
Skin -- Research -- Periodicals
Skin -- Diseases -- Periodicals
Skin -- Physiology -- Periodicals
616.5 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0909-752X&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0846 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/srt.12924 ↗
- Languages:
- English
- ISSNs:
- 0909-752X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8295.948000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16192.xml